00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第445页

User Manual SIPLACE CA-Series 7 Component and Die Handling From software version SC.708.0 Edition 12/20 14 EN -DRAFT 7.5 Docking Station for the SIPLACE X-Series Component Trolley 445 Legend for fig. 7.5 - 5 (1) Control …

100%1 / 518
7 Component and Die Handling User Manual SIPLACE CA-Series
7.5 Docking Station for the SIPLACE X-Series Component Trolley From software version SC.708.0 Edition 12/2014 EN -DRAFT
444
7.5.6 Controls and Displays
7
Fig. 7.5 - 5 Docking station - controls and displays
User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.5 Docking Station for the SIPLACE X-Series Component Trolley
445
Legend for fig. 7.5 - 5
(1) Control lamp for mains power supply
(2) Button for locking and unlocking all feeder modules on the component trolley
(3) Clamping lever for fastening the changeover table - lever in position "closed"
(4) Label with diagram of switch S1 and S2 for addressing the CAN bus
(5) Switch S1 and S2 for setting the CAN bus address
(6) Mains switch
(7) Rotary knob for setting the operating pressure
(8) Manometer for showing the operating pressure
7.5.7 Docking the SIPLACE X-Series Component Trolley onto the Docking Station
7
Open the two horizontal tensioner, by moving them in the direction of the arrow (item 3 in fig.
7.5 - 5
, page 444).
Push the component trolley carefully into the docking station. This will raise the component
table.
Make sure that the component trolley is standing fully on the base plate of the docking station.
Close the two horizontal tensioner (item 3 in fig. 7.5 - 5, page 444.
The changeover table will be lifted to its final position and locked into place.
Use the button (item 2 in fig. 7.5 - 5) to lock/unlock all feeder modules on the changeover ta-
ble.
7.5.8 Undocking the SIPLACE X-Series Component Trolley from the Docking Sta-
tion
7
Open the two horizontal tensioner (item 3 in fig. 7.5 - 5, page 444).
The component table is lowered.
Now pull the component trolley out of the docking station.
WARNING
Only component trolleys from the SIPLACE X-Series may be operated at this docking sta-
tion.
While docking, do not reach into the areas between component trolley and docking
station.
WARNING
While docking, do not reach into the areas between component trolley and docking
station.
7 Component and Die Handling User Manual SIPLACE CA-Series
7.5 Docking Station for the SIPLACE X-Series Component Trolley From software version SC.708.0 Edition 12/2014 EN -DRAFT
446