Fig. 6.4 - 2 Needle kit with vacuum cap removed
Legend
6
Remove the vacuum cap from the needle kit (1).
Loosen the grub screw (2).
Insert the appropriate needle matrix for your product.
Insert all needles carefully into the segments and align the needles in about the same line.
Loosely screw in the grub screws. The needles still have to be movable.
Carry out the following adjustments with the relevant calibration standard.
(1) Vacuum cap (2) Grub screw
1
2
6 Working with the Machine User Manual SIPLACE CA-Series
6.4 SWS Tasks From software version SC.708.0 Edition 12/2014 EN -DRAFT
360
6.4.5.1 Setting the Needle with the Calibration Standard 03080191-xx
Equipment
Needles as spare parts
Calibration standard for the die-ejector (03080191-xx)
With the help of the calibration standard for the die ejector all needles are adjusted into
a defined height and common level. 6
6
Fig. 6.4 - 3 Calibration standard for the die ejector - item number 03080191-xx
User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.4 SWS Tasks
361
6
Fig. 6.4 - 4 Calibration standard for die ejector
Insert the needle unit into the calibration standard for the die-ejector (1). During that the cen-
tering bolt (5) is inserted into the opening on the underside of the ejection unit.
Draw back the ejection unit until it lies fully in the prism. After releasing the crank at the ejec-
tion unit should now be pressed into a defined position against the limiter plate.
Move the alignment plate (2) to the needles not yet clamped.
Move the alignment plate as far as the stop against the bolts, so the needles are adjusted by
the plate in one defined height.
Carefully screw in the grub screws (3) (approx. 10Ncm).
Make sure that no needles have slipped. If they have, loosen the screws again and repeat
the process.
1
5
2
3