5 Setting up and Commissioning User Manual SIPLACE CA-Series 5.4 Infrastructure at the Installation Location From software version SC.708.0 Edition 12/2014 EN -DRAFT 272 5.4.2.2 Compressed Air Connection on the Placement…

100%1 / 518
User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.4 Infrastructure at the Installation Location
271
5.4.2 Compressed Air Supply
5.4.2.1 Checking the Compressed Air Supply
Check whether the compressed air supply complies with the prescribed machine specifications
(see table in section 3.3
, page 126).
5
Record the compressed air characteristics at the installation location.
PLEASE NOTE
Required specifications
To fulfill the required specifications, certain measures are described in the "Network Con-
figuration (Electrics and Compressed Air) for SMD Systems at Customer Site" documen-
tation [00191409-xx].
5 Setting up and Commissioning User Manual SIPLACE CA-Series
5.4 Infrastructure at the Installation Location From software version SC.708.0 Edition 12/2014 EN -DRAFT
272
5.4.2.2 Compressed Air Connection on the Placement Machine
5
Fig. 5.4 - 1 Compressed air line connection
(1) Stop valve in the "OPEN" position
(2) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for gantry distributor supply pressure
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(4) Manometer for the bulk case feeder modules supply pressure
Target pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range: 0 - 0.6 MPa, 0 - 6 bar)
(5) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(6) Compressed air filter
(7) Compressed air connection
(8) Hexagon socket-head screw for fixing the pneumatic unit
5
WARNING
Risk of injuries!
Risk of injuries from pressurized compressed air lines.
NEVER detach compressed air lines while they are still pressurized.
User Manual SIPLACE CA-Series 5 Setting up and Commissioning
From software version SC.708.0 Edition 12/2014 EN -DRAFT 5.4 Infrastructure at the Installation Location
273
5.4.3 Compressed Air Supply to SWS
The compressed air fed to the SWS is directly supplied via the placement machine. (See also
3.3.2
on page 127.)
5.4.4 Mains Supply to Placement Machine
5
Fig. 5.4 - 2 Position of the power supply on the placement machine
5
(1) Lock
(2) Main power switch secured to prevent switching on again
(3) Cover