00197498-03_UM_SiplaceCA-Serie_EN.pdf - 第396页
6 Working with the Machine User Manual SIPLACE CA-Series 6.15 Observing the Indicator Lamps for Operating State s From software version SC.708.0 Edition 12/2014 EN -DRAFT 396

User Manual SIPLACE CA-Series 6 Working with the Machine
From software version SC.708.0 Edition 12/2014 EN -DRAFT 6.15 Observing the Indicator Lamps for Operating States
395
unchanged off on Transport error, left
unchanged off on Machine error, left
Pickup error display
unchanged unchanged flashes (1,20) First track empty, left
unchanged unchanged flashes (5,20) Other tracks empty, left
unchanged unchanged flashes (5,5) Second to last track is being used
unchanged unchanged flashes (1,2) Last track is being used, left
flashes (1,20) unchanged unchanged First track empty, right
flashes (5,20) unchanged unchanged Other tracks empty, right
flashes (5,5) unchanged unchanged Second to last track is being used, right
flashes (1,2) unchanged unchanged Last track is being used, right
L1 (white)
(right lamp)
L2 (green) L3 (white)
(left lamp)
Meaning

6 Working with the Machine User Manual SIPLACE CA-Series
6.15 Observing the Indicator Lamps for Operating States From software version SC.708.0 Edition 12/2014 EN -DRAFT
396

User Manual SIPLACE CA-Series 7 Component and Die Handling
From software version SC.708.0 Edition 12/2014 EN -DRAFT 7.1 X Feeder Modules for SIPLACE X-Series
397
7 Component and Die Handling
7.1 X Feeder Modules for SIPLACE X-Series
SIPLACE X feeder modules are used for SIPLACE X-Series machines. All SIPLACE X feeder
modules are compatible with the SIPLACE X-Series changeover tables. Key properties of the SI-
PLACE X feeder modules include the high precision of the pickup position, online programmability,
status displays on an LCD display and simple handling for feeder module changes during the
placement process. The power supply to the feeder modules is contactless and uses an inductive
interface. Each feeder module communicates with the feeder module control unit (FCU) via two
optoelectronic channels (optical fiber). The two interfaces form the EDIF assembly (energy and
data interface, see item 2 in fig. 7.1 - 1
, page 400). The feeder module control unit is connected
to the control unit of the machine via the CAN bus.
7.1.1 Tape Feeder Modules for the SIPLACE X-Series
7.1.1.1 Tape Material
The tape width spectrum for SIPLACE X-Series machines ranges from 4 mm to 88 mm. The tape
material is blister or paper. Component tapes with a permanently adhesive cover foil (PSA foil)
can also be processed. This will require the "PSA Kit" option.
The design of the tape feeder modules was based on the following tape standards:
DIN EN 60286-3 (12/1998) / IEC 60286-3 (12/1997)
JIS C 0806-3 (1999)
ANSI/EIA 481-C (10/2003)
IEC 60286-3-2 7
PSA Kit Item no.
8 mm X PSA Kit 00141224-xx
12 mm X PSA Kit 00141225-xx
16 mm X PSA Kit 00141227-xx