User Manual SIPLACE CA-Series 2 Operational Safety From software version SC.708.0 Edition 12/20 14 EN -DRAFT 2.8 Safety Features 85 Fig. 2.8 - 4 Position of switches and buttons - view of the PCB input side (1) EMERGENCY…

2 Operational Safety User Manual SIPLACE CA-Series
2.8 Safety Features From software version SC.708.0 Edition 12/2014 EN -DRAFT
84
2.8.2 Switches and Buttons on the Machine and on the SWS
2.8.2.1 Position of Switches and Buttons on the Machine and on the SWS
2
Fig. 2.8 - 3 Position of switches and buttons - view of the PCB output side
(1) Main switch on machine
(2) Stop button (black) on the operator panel on the power supply side
(3) Start button (white) on the operator panel on the power supply side
(4) Component counter on the operator panel on the power supply side
(5) EMERGENCY STOP button on the output side
(6) Start button (white) on the output side
(7) Stop button (black) on the output side
(8) Button (black) for docking the component trolley in or out, location 2
(9) Button (black) for docking the component trolley in or out, location 3
(10) EMERGENCY STOP button on the SWS
(11) Operating status indicator on the SWS
(12) Main Switch at the SWS
(T) PCB transport direction
2

User Manual SIPLACE CA-Series 2 Operational Safety
From software version SC.708.0 Edition 12/2014 EN -DRAFT 2.8 Safety Features
85
Fig. 2.8 - 4 Position of switches and buttons - view of the PCB input side
(1) EMERGENCY STOP button on the input side
(2) Start button (white) on the input side
(3) Stop button (black) on the input side
(4) Start button (white) on the operator panel on the compressed air unit side
(5) Stop button (black) on the operator panel on the compressed air unit side
(6) Button (black) for docking the component trolley in or out, location 1
(7) Button (black) for docking the component trolley in or out, location 4
(8) EMERGENCY STOP button on the SWS
(9) Operating status indicator on the SWS
(10) Main Switch at the SWS
(T) PCB transport direction

2 Operational Safety User Manual SIPLACE CA-Series
2.8 Safety Features From software version SC.708.0 Edition 12/2014 EN -DRAFT
86
2.8.2.2 Function of Switches and Buttons on the Machine
Main switch in OFF position (see item 1 in fig.
2.8 - 3) 2
The main power switch disconnects the three phases L1, L2, and L3 from the power supply.
2
Main switch in ON position 2
After switching on the main power switch, the control computer and the machine controller will
start. All supply voltages, apart from the link voltages for the gantry axes (250 VDC) and the star
axes (145 VDC) are then available.
Stop button, black (items 2 and 7 in fig. 2.8 - 3 and items 3 and 5 in fig. 2.8 - 4) 2
These buttons are used to stop the machine.
Start button, white (items 3 and 6 in fig. 2.8 - 3 and items 2 and 4 in fig. 2.8 - 4) 2
After switching on the main power switch you will be prompted to press the start button in order to
start the machine for placement jobs. The same prompt appears if you open the protective covers
or the press the EMERGENCY STOP button.
Component counter (item 4 in fig. 2.8 - 3) 2
This displays the number of inserted components.
DANGER
Lethal voltages!
Incorrect handling of the machine can therefore result in death or severe injury or consid-
erable damage to equipment.
The following components still carry potentially lethal voltages even if the main power
switch is switched off:
– Cable connection terminals L1, L2, and L3 of the Q1 main power switch
– Z1 line filter
– Service socket X102
– F1 automatic circuit breaker for the service socket
– The color of all individual wires, which still carry potentially lethal voltages even if the
main power switch is switched off, is brown.
Always follow the applicable accident prevention and DIN regulations (particularly EN
60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own coun-
try.
The safety door to the power supply must ONLY be opened by appropriately qualified
and trained personnel.