YRM20_Ope_E.pdf - 第142页

3. Displaying the production monitors 2-45 Chapter 2 Basic operation • Nozzle T ype Indicates the type of nozzle. • Nozzle Stn No Indicates the setup position of that particular nozzle on the nozzle station. • V acuum Ch…

100%1 / 220
3. Displaying the production monitors
2-44
Chapter 2 Basic operation
3.11 Nozzle health check
This screen appears only when the "Nozzle Health Check" on [Machine Information] - [Installation Setting]
of the machine setting is set to "Use".
The nozzle health check is a function that does the tasks individually performed in the previous section
"3.10 Schedule task" in a comprehensive, batch manner. The “Nozzle Health Check” screen shows the
nozzles in bad condition.
The nozzle health check goes through a sequence in the order of 1. Vacuum Check
2. Nozzle Tip
Cleanliness Check
3. Buffing Check
4. Shape Check
5. Alignment Check. If the nozzle fails any of
them (NG), the machine no longer checks that particular nozzle.
Monitor: Nzl Hlth Chk (Nozzle health check)
24223-KMX-00
[Health Check] button
Pressing this button calls up the nozzle health check screen. Specify the object table (head unit) and
object ranges and press the [OK] button. The machine goes through the nozzle health check.
The object ranges are “All (all nozzles)”, “Board data (nozzles to be used so designated by the board
data)” and “NG (a nozzle designated to be NG after going through the nozzle health check once)”.
Check Result Display Scope
This designates the range of nozzle health check results.
Select either “All”, “Board data” or “NG” to have the corresponding results appear on the screen.
• Result
This shows the results of the nozzle health check. If resulting in “NG”, the corresponding row on the
screen is displayed in red.
Note that the result is “NG” if the nozzle fails any one of the check items.
• Table
Select the object table.
• Head
Indicates the head number used.
3. Displaying the production monitors
2-45
Chapter 2 Basic operation
Nozzle Type
Indicates the type of nozzle.
Nozzle Stn No
Indicates the setup position of that particular nozzle on the nozzle station.
Vacuum Check, Tip Cleanliness Check, Buffing Check, Shape Check, Alignment Check
These indicate the results of the schedule tasks individually.
[Result Detail] button
Selecting a row with an NG result and pressing the [Result Detail] button shows the details of NG item.
TIP
If ticking the checkbox of “Don’t start running if Nozzle Health Check NG is detected” on “Setup” screen – “Software
Setting” – “Basic” tab – “Nozzle health check”, an error message appears at the time of starting the operation so as not to
use the “NG” nozzle for the production. If providing this parameter with a check mark, it is necessary to clean or replace
the failed nozzle and once again go through the nozzle health check.
“Nozzle Health Check” setup screen
[Health Check] button [Software Setting] button
24224-KMX-00
3. Displaying the production monitors
2-46
Chapter 2 Basic operation
3.12 Gap of pick-up position
Displays the gap between the component center calculated by component recognition and the center of
camera field angle, for each component specified in board data, in graph form.
The re-examining of pick-up position or pick-up nozzle may be required for the component with large value
variability or biased recognition results in this graph.
Monitor: GapOfPickPos (Gap of pick-up position)
24225-KMX-00
n
NOTE
The displayed threshold of the gap of pick-up position amount can be specify to any value by selecting "Set" from [Parts]
- [Option] - [Pick Pos Check].
When [Normal] is selected for [Pick Pos Check], one-third of an opposite side of part size XY is specified automatically as
threshold of the gap of pick-up position amount.