4. Component supply section 1-44 Chapter 1 Unit names and functions Moreover , sensors are equipped to detect upper cover at carriage set position of machine. The upper cover end plate detection sensor detects attaching …

100%1 / 220
4. Component supply section
1-43
Chapter 1 Unit names and functions
Temporary placing of upper cover and precautions
The upper cover can be placed temporarily upon handles of feeder exchange carriage.
Also, a cover identification label attached to upper cover carries machine serial number and number of
carriage set position.
The upper cover is not compatible for other carriage set position or other machine, as the guide position
is adjusted for the correspond machine upon assembling and then the carriage is shipped. Use with the
machine/carriage set position written on cover identification label.
Temporary placing of upper cover
Cover identification label
23128-KMX-00
4. Component supply section
1-44
Chapter 1 Unit names and functions
Moreover, sensors are equipped to detect upper cover at carriage set position of machine.
The upper cover end plate detection sensor detects attaching fault of cover end plate, and the upper
cover safety switch detects whether the cover closes correctly.
When even one fault is detected by these two sensors, automatic operation cannot start.
Sensors for upper cover
Upper cover end plate detection sensor
Upper cover safety switch
Upper cover end plate detection sensor
Normal Upper cover attaching fault
Normal Upper cover unfinished attaching
Upper cover safety switch
23129-KMX-00
4. Component supply section
1-45
Chapter 1 Unit names and functions
4.3 One-stop cover (option)
When the automatic operation is required to start without feeder exchange carriage, attach one-stop cover
instead of carriage. The one-stop cover prevents putting hands and fingers in moving section.
One-stop cover
One-stop cover
23130-KMX-00
n
NOTE
The one-stop cover cannot be detached during automatic operation.
Assembling one-stop cover
The one-stop cover is normally delivered in folded.
1. Remove two knobs from one-stop cover by hand.
2. Unfold one-stop cover.
3. Attach knobs removed in 1. on front surface of one-stop cover.
Assembling one-stop cover
Knob
23131-KMX-00