YRM20_Ope_E.pdf - 第98页

1. Before operation 2-1 Chapter 2 Basic operation 1. Before operation The following explains how to cancel emergency stop and clear errors. Read befor e operating the machine. █ Cautions during machine operation • Do not…

100%1 / 220
4. Preparing component tape 2-47
4.1 Tape feeders 2-47
4.1.1 Setting component tape on the feeder 2-47
4.1.2 Setting feeders on the feeder exchange carriage 2-57
4.1.3 Attaching the feeder exchange carriage on the mounter 2-61
4.1.4 Setting board data of component tape 2-64
4.1.5 Disposing of used cover tape and carrier tape 2-66
4.1.6 Detaching the feeder exchange carriage 2-69
4.1.7 Detaching feeder from the feeder exchange carriage 2-71
4.1.8 Detaching component tape from feeder 2-72
4.2 SS Feeder 2-75
4.2.1 Setting SS feeder on the feeder exchange carriage 2-76
4.2.2 Attaching the feeder exchange carriage on the mounter 2-78
4.2.3 Detaching the feeder exchange carriage from mounter 2-80
4.2.4 Detaching SS feeder from carriage 2-82
1. Before operation
2-1
Chapter 2 Basic operation
1. Before operation
The following explains how to cancel emergency stop and clear errors. Read before operating the
machine.
Cautions during machine operation
Do not turn off the compressed air during operation. The machine may malfunction, as pneumatic
devices are not correctly controlled.
Before beginning maintenance, switch off the air-supply as needed. Before that, if there is the
residual pressure releasing valve, make sure to open it to release the residual pressure.
Cautions during power outages
If a power outage (blackout) occurs during automatic machine operation, always turn the main power
switch off to prevent faulty operation or machine damage after power has been restored. Also remove
the boards that remain in the machine.
1.1 Canceling emergency stop
Follow these steps to cancel emergency stop.
1
Release the emergency stop button.
When the emergency stop button is pressed, turn it clockwise to release it.
2
Check safety.
Before continuing the procedure, check the surrounding area for safety.
3
Press the [READY] button.
Pressing the [READY] button on the operation panel turns on the servomotors.
c
CAUTION
The [READY] button is enabled only when the [ACTIVE] button next to it is active.
[READY] button
Operation display
Emergency stop button
[READY] button
23200-KMX-00
4
Check the signal light and screen display.
Check that the red lamp of the signal light is off and the emergency stop sign on the top left (status
area) of the operation screen is now off.
1. Before operation
2-2
Chapter 2 Basic operation
1.2 Clearing an error
If an error occurs a buzzer sounds and a warning screen appears. To clear the error, use the following steps.
1
Turn off the buzzer.
Press the [ERROR CLEAR] button on the operation panel or the [BUZZER OFF] button on the error
screen to turn off the buzzer.
2
Check the cause of the error.
Possible causes are displayed on the lower part in the error screen, so check or make a note of the
description.
3
Clear the error screen.
Press the [ERROR CLEAR] button again or the [ERROR CLEAR] button on the error screen to clear the
error screen.
4
Check the signal light and screen display.
Check that the yellow lamp of the signal light is off and the error message on the left of the status
area on the operation screen is now off.
Error screen
Mark detection error
[BUZZER OFF] button [ERROR CLEAR] button
24200-KMX-00