YSP_Users_E.pdf - 第135页

4-32 4 Creating and setting the data 7. Creating the mark data This section describes how to create fiducial mark data used on boards and masks. Mark data has various parameters for each of the mark names registered as s…

100%1 / 278
4-31
4
Creating and setting the data
l
Detailed setting for time count control
On the [Print]-[Cleaner] tab, set the “Cleaning Method” to “Auto” and the “Auto Cleaning Type” to “Detail”. Then, in the
“Interval (min.)” parameter, enter the time interval to perform cleaning.
Then, press the [Detail Setting] button to open the “Cleaning Detail Setting” screen. Select the [Controlled …Time] tab
and set the cleaning type, speeds, and vacuum suction.
This tab does not have a “Detail Auto Interval” box, and only one cleaning operation can be registered.
[Print] - [Cleaner] tab
[Detail Setting] button
64455-L3-00
4-32
4
Creating and setting the data
7. Creating the mark data
This section describes how to create fiducial mark data used on boards and masks. Mark data has various
parameters for each of the mark names registered as shown below. You can directly enter or select these
parameters, but you need to check or optimize some parameters in the Mark Adjust mode explained later.
Mark data parameters
Surface Type
Algorithm Type
Mark Threshold
Tolerance
Search Area
Outer Light
Inner Light
Coaxial Light
IR Outer Light
IR Inner Light
Cut Outer Noise
Cut Inner Noise
Mark Type
Database Number
Shape Type
Mark Out Size
(Mark Out Size X)
(Mark Area)
(Outline)
Mark Name
Comment
(Mark Type)
63418-L3-00
TIP
Actual parameters that appear depend on the selected "Shape Type" parameter, etc.
4-33
4
Creating and setting the data
7.1 Creating procedure
Pressing the Mark button in the menu button area opens the Mark screen as shown below. Enter the mark name
and comment in the data No. list on the upper part of the screen, and set the parameters in the right lower list
as explained below.
1
Press the [Mark] button to open the Mark screen.
Step 2 Step 1 Step 3
Step 5
Step 4Step 7
Mark screen
64427-L3-20
2
Enter the mark name in the Mark Name cell.
Enter a different name for each mark within 20 alphanumeric characters. A space cannot be included
in the name.
3
Enter a comment.
Type any desired comment in the Mark Comment cell as necessary. You can omit entering comments
here.
4
Set the various necessary parameters.
While selecting the [Basic], [Shape] and [Vision] tabs, set the necessary parameters in the right lower list.
You can also copy the parameter values from the database by pressing the [Database] button to open
the database list. In this case, the database No. of the copy source appears in the "Database Number"
field. (See "7.2" to "7.4" in this chapter.)
5
Adjust the parameters in the Mark Adjust mode.
Pressing the [Adjust] button opens the Mark Adjust screen that allows you to adjust or check the
parameters. (For more details, see "7.5 Mark Adjust mode" in this chapter.)
6
Repeat the above steps for other marks.
Repeat the same procedure to register all marks to be used.
7
Save the data.
Press the [Save] button to store the board data.