JaNets Instruction Manual 5. Shopfloor Setup
5-22
Machine details
Set the basic information on a machine and the condition of each device. The items you set here
are reflected on the machine view screen visually.
Figure 5.4-8 Machine details screen
How to make the settings:
① Set data on each tab: “Basic Settings,” “Standard Devices,” “Option Devices” and “Operation
Options” in this order.
(When you select the “Standard Devices” tab after entering the IP address, the system
automatically checks the entered IP address, and then switches the “Basic Settings” tab to
the “Standard Devices” tab.)
* When a machine arranged in the line being monitored is selected, all the setting items of
basic setting, standard unit, option unit and operation option cannot be changed (displayed
in gray).
* When a machine arranged in the line in the EPU mode is selected, the status getting
button cannot be operated. (Displayed in gray)
* When a machine arranged in the line in the EPU mode is selected, the IP address cannot
be checked automatically.
OK: Validates the changes when you change the
settings of the machine details.
Undo: Discards the changes when you change
the settings of the machine details, and
restores them to the conditions you validated
last time.
Learn Conditions: Communicates to the machine
whose IP address/computer name is specified
to obtain the “Machine Type” and the detailed
information on the machine.
Permanent Information: Displays the
“Permanent Feeders” setting screen and the
“Permanent Nozzles” setting screen.
Connection Test:
Communicates with a
machine whose IP address/computer name
is specified in order to check to see if it is
connected to the system.
* This Connection Test function does not
guarantee the machine model connected to
the system. It checks response to the
specified machine.

JaNets Instruction Manual 5. Shopfloor Setup
5-23
Basic Settings
Figure 5.4-9 “Basic Settings” tab
Standard Devices/Option Devices/Operation Options
* The displayed items vary depending on the specifications of a machine.
Check box: Specify what device is attached to a machine (Select the "Use" or "Not use" for
Standard Devices.)
The "Use" or "Not use" selection button:
Select the "Use" or "Not use" of the device.
1) Example of a RX-6
Figure 5.4-10 Standard Devices (RX-6)
Machine Type: Select the machine type
(model name). When a machine is
assigned to a production line, you
cannot change its machine type here.
IP Address/Computer Name:
Set the IP address or the computer
name (you have to set either one here).
When it is arranged in the EPU mode,
no data is displayed.
Machine Version: Displays the machine
communication version.
Select the component height:
EC: 6mm
NC:12mm
HC: 20mm
EC: 25mm
UC: 33mm

JaNets Instruction Manual 5. Shopfloor Setup
5-24
Figure 5.4-11 Option Devices (RX-6)
Figure 5.4-12 Operation Options (RX-6)
* Operation options cannot obtain information with the "Learn Conditions."
The device that cannot be attached at the same time cannot be selected.
Items that can be set with the Machine Setup utility on the machine main unit
are displayed here. You cannot select any item that cannot be set with the
Machine Setup utility.
Select the recognition type
of a standard VCS:
- None
- Side Recognition
- Bottom Recognition
- Side, Bottom
Attaching position of IC Collection Belt
- Mechanical feeder bank
Specify hole number of left end of occupying width.
- Electric feeder bank
(Only machine type to be set.)
Specify the third hole number (center) of left end of
occupying width.