JANETS_INM.pdf - 第270页

JaNets In structio n Manual 7. Program Editor 7- 63 Component insertion error detecting function (JM - 20 S eries ) Figure 7.4 - 90 “ Component inserti on error detec ting function ” (JM - 20 serie s ) screen T able 7.4 …

100%1 / 755
JaNets Instruction Manual 7. Program Editor
7-62
Setting for determining the component direction
Figure 7.4-89Setting for determining the component directionscreen
Table 7.4-54 Items displayed on the Setting for determining the component directionscreen
Item
Description
Determination
Yes/No
Select whether to determine the component direction with the corresponding radio button.
The “No” radio button is selected by default.
Setting for determin-
ing the component
direction
method
You can enter this field when you select the “Yes” radio button of the menu item “determi-
nation.” Select the determining method among “Lead,” “Package” and “Chamfering.”
The “Lead” radio button is selected by default.
When you select a pickup nozzle, “method (Pickup Nozzle)” is displayed as the menu item.
When you select a gripper nozzle, “method (Gripper Nozzle)” is displayed.
Setting for determin-
ing the component
direction
Threshold
You can enter this field when you select the “Yes” radio button of the menu item “determi-
nation.” Enter the reference value for deciding the direction.
Input range: - 2.0000 to 2.0000 mm Default value: 0.0000 mm
Setting for determin-
ing the component
direction
Margin (±)
You can enter this field when you select the “Yes” radio button of the menu item “determi-
nation.” Specify the margin (±) of the threshold value that does not generate any error for
the measurement result.
Input range: 0.0000 to 55.00 mm Default value: 1.00 mm
Setting for determin-
ing the component
direction
Height
You can enter this field when you select “Yes” for the menu item “determination” and
“Package” or “Chamfering” for the menu item “method.” Enter the height of a component
to be applied when a package is recognized.
Input range: 0.00 to 55.00 mm Default value: 1.00 mm
Setting for determin-
ing the component
direction
Angle
You can enter this field when you select “Yes” for the menu item “determination” and
“Chamfering” for the menu item “method.” Enter the angle to be applied when the system
decides the component direction.
Input range: - 90.00 to 90.00 degrees Default value: 0.00 degrees
Setting for determin-
ing the component
direction
Pickup correction
height
You can enter this field when you select “Yes” for the menu item “determination” and “Lead”
or “Package” for the menu item “method.”
However, you cannot enter this field when you select a gripper nozzle regardless of the
setting of the menu item “method.”
Enter the component pick-up correction height to be applied when the system decides the
component direction.
Input range: 0.00 to 55.00 mm Default value: “Component height” 0.3 mm
JaNets Instruction Manual 7. Program Editor
7-63
Component insertion error detecting function (JM-20 Series)
Figure 7.4-90Component insertion error detecting function(JM-20 series) screen
Table 7.4-55 Menu items displayed on the
Component insertion error detecting function(JM-20 Series) screen
Item Description
Check
Yes/No
Select whether to detect a component insertion error with the JM-20 with the corresponding
radio button.
You can select this menu item only when “Insertion component” or “INS electrolytic capacitor
is selected as the component type.
The “No” radio button is selected by default.
Normal judgment
range
Set the normality judgment range based on the data obtained with the JM-20.
A total of the torque ratio in normal operation and the value specified here becomes the upper
limit of this range, while the value specified here subtracted from the torque ratio becomes
the lower limit of this range.
Data obtaining
condition
Shows the torque ratio obtaining condition. Not obtained” or “Obtained” is displayed here.
Component insertion error detecting function (JM-10 Series)
Figure 7.4-91Component insertion error detecting function(JM-10 Series) screen
Table 7.4-56 Menu items displayed on the
Component insertion error detecting function(JM-10 Series) screen
Item
Description
Check
Yes/No
Select whether to detect a component insertion error with the JM-10 with the corresponding
radio button.
You can select this menu item only when “Insertion component” or “INS electrolytic capaci-
tor” is selected as the component type.
The “No” radio button is selected by default.
Normal judgment
range
Set the normality judgment range based on the data obtained with the JM-10.
A total of the torque ratio in normal operation and the value specified here becomes the
upper limit of this range, while the value specified here subtracted from the torque ratio
becomes the lower limit of this range.
Data obtaining
condition
Shows the torque ratio obtaining condition. Not obtained” or “Obtained” is displayed here.
JaNets Instruction Manual 7. Program Editor
7-64
Component insertion error detecting function (JM-100 Series)
Figure 7.4-92Component insertion error detecting function(JM-100 Series) screen
Table 7.4-57 Menu items displayed on the
Component insertion error detecting function(JM-100 Series) screen
Item
Description
Check
Yes/No
Select whether to detect a component insertion error with the JM-10 with the corresponding
radio button.
You can select this menu item only when “Insertion component” or “INS electrolytic capaci-
tor” is selected as the component type.
The “No” radio button is selected by default.
Normal judgment
range
Set the normality judgment range based on the data obtained with the JM-10.
A total of the torque ratio in normal operation and the value specified here becomes the
upper limit of this range, while the value specified here subtracted from the torque ratio
becomes the lower limit of this range.
Data obtaining
condition
Shows the torque ratio obtaining condition. Not obtained” or “Obtained” is displayed here.
Setting for a feed operation of the radial feeder
Figure 7.4-93Setting for a feed operation of the radial feederscreen
Table 7.4-58 Items displayed on the Setting for a feed operation of the radial feederscreen screen
Item Description
Use
No/Yes (An HMS
check is made)
Yes (No HMS check
is made)
You can set this menu item when
- the component type is “Insertion component” or “INS electrolytic capacitor”
-“INS Tape” is selected, and the type is “MRF-S” or “MRF-L.”
Select whether to perform a feed operation or not among “No” (default), “Yes (An
HMS check is made)” and “Yes (No HMS check is made).”
Continuous number of
components Com-
ponent
Specify the number of components from a missing component position to the next
missing component position.
Default: 1
Input range: 1 9999
Continuous number of
components
No components
Set the number of missing components.
Default: 1
Input range: 1 255