JaNets Instruction Manual 13. Program Downloader
13-46
13.10.2.5 Cancelling the association
The <Remove Relation> button deletes information on a production program from the information
on the serial code and production program association. Select association data to be deleted
from the list, and then click the <Remove Relation> button. The association of the serial code
and the production program is canceled, and only the serial code is displayed on the “Association
of a serial code” screen.
Figure 13.10-7 Cancelling the association

JaNets Instruction Manual 13. Program Downloader
13-47
13.10.2.6 Deleting a serial code
The <Delete a serial code> button deletes a serial code and information on its associated
production program from association information of the serial code and the production program.
Select data to be deleted from the list, and then click the <Delete a serial code> button. The
selected data is deleted from the list.
Figure 13.10-8 Deleting a serial code
13.10.2.7 Saving the association information
When you click the <Apply> button, the association information is saved.
13.10.2.8 Terminating association operation of a seral code and a production program
When you click the <OK> button or the <Cancel> button, the system terminates association
operation. When you click the <OK> button, the system saves the association information before
terminating the association operation. When you click the <Cancel> button, it does not save the
information.

JaNets Instruction Manual 13. Program Downloader
13-48
13.10.3 Associating a serial code with a production program
(Data Manager)
To associate a seral code with a production program that is saved to the Data Manager, you have
to select the “Data Manager” radio button for the menu item “Search” of the setting item
“Management of production program” on the “Set Environments” screen of the Program
Downloader (see Section 13.14.2.7).
<Note>
Even though you make the setting as described above, if the Data Manager connection license is
invalid or if the Data Manager is set to be unused with the JaNets launcher, the association screen
for a serial code and a production program saved locally appears.
See Section 17.3.9 “Associating a serial code with a production program” of Chapter 17 “Program
Explorer” for how to associate them.
13.10.4 Opening a production program associated with a serial code
Open the production program associated with the read serial code.
The target to be searched for is decided according to selection of the “Search” radio button of the
setting item “Management of production program” on the “Set Environments” screen of the
Program Downloader (see Section 13.14.2.7).
13.10.4.1 Calling the seral code reading screen
Select the menu commands: [File] – [Open with a Serial code] from the menu bar, the screen for
reading a serial code is displayed.
Figure 13.9-9 [Open with a Serial code] menu command
Figure 13.9-10 Screen for reading a serial code
The target association information to be searched for (Local/Data Manager) is displayed on the
title bar of the screen.
Data Manager