JANETS_INM.pdf - 第413页
JaNets Instr ucti on Man ual 8. Job Optim izer 8- 28 The contents to be out put by reserv ation list, compo nent hist ogram or feed er s etup inform ation ar e items set in th e display ite m of t he dialog disp lay ite …

JaNets Instruction Manual 8. Job Optimizer
8-27
Save as Text
Figure 8.3-47 Main screen – [File] – [Save as Text]
Figure 8.3-48 “Save as Text” dialog box
* Set the menu items “What to Save” and “Configuration” in
the same way as you set those on the “Print” dialog box ①
of Figure 8.3-40.
Select the [File] command,
and then the [Save as Text]
command.
When you select one of the "Specify Saving Items" group, the <Save as Text> button
becomes available.
This button allows you to
change the file name or
the output folder.

JaNets Instruction Manual 8. Job Optimizer
8-28
The contents to be output by reservation list, component histogram or feeder setup information are
items set in the display item of the dialog display item setting of “8.3.27 Set Environments.”
Each item can be selected in the above dialog box under the condition described in the table
below.
Table 8.3-3 Conditions under which each of the items of
the “Specify Saving Items” group can be selected
Item
Condition under which each item can be selected
Reservation List/Component Histogram
After a production program is added
Optimization Options
After a production program is added
Feeder/Nozzle Layout
After optimization is completed
Component Count/Divided Placement
Data
After optimization is completed
Feeder Setup Information
After optimization is completed, and either of the feeder
arrangement options “Common feeder is fixed” or “No
feeders are replaced on the cluster” is selected.
Number of Feeders
After optimization is completed
Figure 8.3-49 “Save as Text” dialog box (Browse) – “Selecting a file”
Default output file name:
set as the “Reservation file folder of the selected line (to be set with the Shop
Floor Setup) + Year (4 digits) folder + Month (2 digits) folder + Reservation file name.csv.” The path of a
reservation file and the reservation file name format are to be set with the Shop Floor Setup.
Example: C:\Juki\JaNets\Data\Line001\2014\05\20140505170930.csv
File type: The text file (*.csv) format it selected.

JaNets Instruction Manual 8. Job Optimizer
8-29
Feeder Layout
When you select the commands, [View]-[Feeder Layout], the layout screen appears.
Figure 8.3-50 Main screen – [View] – [Feeder Layout]
The Job Optimizer allows you to move a cluster of feeders.
Note that a feeder can be moved only if the following requirements are satisfied:
- A reservation file is optimized when the radio button “Fix all feeder positions within a cluster” is
selected on the “Multi-optimize Options” screen invoked from “Optimize” command.
- A cluster is selected on the “Feeder Layout” screen, and “ALL” is selected for the menu item
“Specify Production Program.”
To move a feeder to a different machine, the cluster number should be the same. After you change
the feeder layout (that is, quit the “Feeder Layout” screen), this layout information is stored in the
production program.
Therefore, the program is put in the not-optimized state (the cluster information is cleared also), so
you have to execute the optimization function again.
Note that any reference feeder is not considered.
* When optimization is not executed or
the production program is changed after
optimization, any selection cannot be
made.