JANETS_INM.pdf - 第213页
JaNets In structio n Manual 7. Program Editor 7-6 Editing PWB Data (Basic Dimension S ettings) When you se lect the “ PWB Da t a ” fro m the tree view , and then the “ Basic Dim ension Sett ings, ” the followin g screen …

JaNets Instruction Manual 7. Program Editor
7-5
Bad mark teaching
information
Select the setting method of bad mark teaching information from between "Use data of the
machine" and "Use data of the production program."
Global bad mark
Select the check method at the time of detecting a global bad mark from between "Check
with mark detection" and "Not check with mark detection."
Figure 7.4-2 Warning message for Substrate ID
[In Case of the Line only for JM-10 and JM-20]
Placement circuit specification, vacuum table, feed forward for printing offset, bad mark teaching
information and global bad mark are not indicated.
[In Case of the Line Including JM-100]
Feed Forward of Vacuum Table and Print Misalignment becomes non-display.

JaNets Instruction Manual 7. Program Editor
7-6
Editing PWB Data (Basic Dimension Settings)
When you select the “PWB Data” from the tree view, and then the “Basic Dimension Settings,” the
following screen appears.
Figure 7.4-3 PWB data (PWB Dimension Settings) screen
Table 7.4-2 PWB data (PWB Dimension Settings) screen
Item Description
PWB Dimensions
Set up the outer dimensions of a PWB.
Reference Hole Position Set up the positioning hole position seen from a PWB position reference.
This item can be set up only when "Reference Hole Position” is selected as the
method of positioning a PWB.
PWB Layout Offset
Set up the coordinates of the PWB layout edge point seen from a PWB position
reference.
A PWB layout edge point changes depending on a transport direction and a ref-
erence surface.
PWB Height Set up the height of PWB surface seen from the transport reference surface.
[When a JX-350 is used]
“0” (zero) is always displayed regardless of what value you entered.
PWB Thickness
Set up the thickness of a PWB.
Back Height
Set up the distance including the component height to the back side of a PWB
seen from a transport reference surface.
Clamp offset
Set up the clamp offset which detects a PWB edge point with an HMS at the time
of the second clamp of a large-sized board.
Whenever the PWB outer dimensions Y changes, default of the clamp offset is set
up.
Head height at production
start
This item is displayed when an RS-1 and JM-100 included in the production line.
Enter the maximum height of a component already placed on a board with the
previous process of the JaNets.
Since a blank is displayed for this item by default, the PWB data cannot be created
completely unless you enter this item.
Every clamp place range
X1
This item is displayed when a JX-350 is used.
If the X-dimension of the board outer dimensions “PWB Dimensions” exceeds 650
mm, enter the range in which a component is placed when the board is clamped
for the first time.
Every clamp place range
X2
This item is displayed when a JX-350 is used.
If the X-dimension of the board outer dimensions “PWB Dimensions” exceeds
1200 mm, enter the range in which a component is placed when the board is
clamped for the second time.
PWB Place height
This item is displayed when a JX-350 is used.
You cannot edit this setting.
A value calculated based on the board height set in the “PWB Height” field and the
board thickness set in the “PWB Thickness” is displayed here.
* The unit of the length displayed here
is specified with the Shopfloor Setup
application, and you can set the
length in mm or inch.

JaNets Instruction Manual 7. Program Editor
7-7
Editing PWB Data (Circuit Settings)
When you select the “PWB Data” from the tree view, and then the “Circuit Settings A,” the following
screen appears.
Figure 7.4-4 PWB data (Circuit A settings) screen
When you press the <Advanced> button, the BOC mark information for each machine can be
displayed or set.
Only RX-6/RX-7/RS-1/JM-100 can set the BOC mark.
The <Advanced> button is enabled only when two or more BOC mark positions are set or two or
more second BOC mark positions are set.
[When a JX-350 is used]
The area in which you are supposed to enter information on the third BOC mark is displayed.
It is displayed on the “Advanced settings” screen and the “Teach Status” screen also.
[In Case of the Line only for JM-10 and JM-20]
None of the menu item “Global bad mark,” the <Advanced> button and the <RX-7 series mark
data> button are displayed on the screen.
[In Case of the Line including JM-100]
RX-7 series Bad Mark Information becomes non-display.
Displays the “Teach Status” dialog.
Displays “Advanced settings” dialog.
Displays the dialog box
for setting bad mark
data to be used with an