00191025-01.pdf - 第494页

SIPLACE 80S/F/G User’s Manual 10 SIPLACE G Edition 07/97 from S oftware Version SR.010.xx 10.5 E rror Menus 10 - 27 Continue glueing In order to continue the glueing p rocess, u se the curs or keys to s elect the me nu i…

100%1 / 736
10 SIPLACE G SIPLACE 80S/F/G User’s Manual
10.5 Error Menus Edition 07/97 from Software Version SR.010.xx
10 - 26
Cycle mode
Use the cursor keys to move the cursor bar onto the menu item "Cycle mode". Then press the
Return key
.
For each step of the glueing sequence you must now press the start key.
10.5.3 Fiducial Errors Menu
If a fiducial is not found or is not recognized during the course of position recognition, the fiducial error menu
will appear automatically on the screen.
Fig. 10.5.2
10.5.3.1 Range of Functions - Operator
Display errors
In order to display all errors which have occurred, use the cursor keys to select the menu item "Display
errors" and press the
Return key
. On the screen the menu described in Section 10.6 "Display Functions":
"Display errors" appears.
Abort glueing
In order to leave the error menu without continuing the glueing process, use the cursor keys to select the
menu item "Abort glueing" and press the
Return key
. The board on the conveyor will be moved on to the
output conveyor. The gantry will be brought into the stand-by position.
SI 80G V 10.x
Cluster: TEST
Neuer Nutzen
Display errors
Confirm errors
Machine options
Error
State
Action
:
:
:
Error treatment - fiducial errors
Abort glueing
PCB to output conveyor
PCB to center conveyor
Display errors
Continue glueing
Fiducial errors
Continue glueing
Glueing adjustmts
SIPLACE 80S/F/G User’s Manual 10 SIPLACE G
Edition 07/97 from Software Version SR.010.xx 10.5 Error Menus
10 - 27
Continue glueing
In order to continue the glueing process, use the cursor keys to select the menu item "Continue glueing"
and press the
Return key
. The machine checks whether there is a board on the center conveyor (glueing
area) and continues the glueing procedure. If there is not a board in the glueing area, under menu item
"Action" of the basic menu a request will be made.
PCB to output conveyor
When the function "PCB to output conveyor" is selected by means of the cursor keys and
Return key
, a
board which is on the center conveyor will be transported on to the output conveyor and left there for man-
ual removal. Any components which have already been picked up will remain on the placement head.
PCB to center conveyor
When the function "PCB to center conveyor" is selected by means of the cursor keys and the
Return key
, a
board which is on the input conveyor will be transported to the center conveyor, stopped and clamped.
10.5.3.2 Range of Functions - Line engineer
Once the
line engineer password
has been typed in the following additional functions will be displayed in the
transport errors menu:
Cycle mode
Use the cursor keys to move the cursor bar onto the menu item "Cycle mode". Then press the
Return key
.
For each step of the glueing sequence you must now press the start key.
10 SIPLACE G SIPLACE 80S/F/G User’s Manual
10.5 Error Menus Edition 07/97 from Software Version SR.010.xx
10 - 28
10.5.4 Cartridge 1/2/3 Empty
The error menu "Cartridge 1/2/3 empty" is shown on the screen when the cartridge in question is empty.
NOTE
If a cartridge becomes empty during glueing the message "Not enough glue for the next LP" will appear on the
screen.
Fig. 10.5.3
10.5.4.1 Range of Functions - Operator
Display errors
In order to display all of the errors which have occurred, use the cursor keys to select the menu item
"Display errors" and press the
Return key
. On the screen the menu described in Section 10.6 (Display
Functions): "Display errors" appears.
Abort glueing
In order to leave the error menu without continuing the glueing process, use the cursor keys to select the
menu item "Abort glueing" and press the
Return key
. The board on the conveyor will be moved on to the
output conveyor. The gantry will be brought into the stand-by position.
SI 80G V 10.x
Cluster: TEST
Neuer Nutzen
Display errors
Confirm errors
Machine options
Error
State
Action
:
:
:
Error treatment - cartridge empty
Abort glueing
Gantry functions
Display errors
Continue glueing
Cartridge 1/2/3 empty
Continue glueing