00191025-01.pdf - 第679页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 92 817 DP: Set-up without valid machine data CAUSE ● Incorrect da ta supply from the line computer…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 91
810 KLKONF: System error during send message
CAUSE
●
Software error in glueing configuration task during send message
REMEDY
●
Reboot
811 KLKONF: Incorrect input
CAUSE
●
Software error in glueing configuration task; Incorrect message received
REMEDY
●
Reboot
812 KLKONF: Invalid input data
CAUSE
●
Software error in glueing configuration task; Incorrect data received from data preparation
REMEDY
●
Reboot; get the data organized
813 WARNING: Glue data from file ".ZKL" invalid
CAUSE
●
1. No *.ZKL can be found (with glueing parameters which have not yet been manipulated).
2. Data from "ZKL" incorrect.
REMEDY
●
To 1. Not an error
To 2. Delete *.ZKL, manipulate, then a new *.ZKL will be created.
814 Glueing data cannot be modified
CAUSE
●
Software error
REMEDY
●
Reboot
815 DP: Incorrect operating system call
CAUSE
●
Software error
REMEDY
●
AUT 5V Service or AUT 5 BSM14 (Development) should be notified.
816 DP: No LC command in service without LC
CAUSE
●
Machine in "service without line computer" but all the same command received via IEC bus.
REMEDY
●
Machines and line configuration should be checked.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 92
817 DP: Set-up without valid machine data
CAUSE
●
Incorrect data supply from the line computer.
REMEDY
●
Data supply from the line computer should be checked.
818 DP: Cluster without valid set-up data
CAUSE
●
Incorrect data supply from the line computer.
REMEDY
●
Data supply from the line computer should be checked.
819 DP: Package form without valid set-up data
CAUSE
●
Incorrect data supply from the line computer.
REMEDY
●
Data supply from the line computer should be checked.
820 DP: Delete package form without valid set-up data
CAUSE
●
Incorrect data supply from the line computer.
REMEDY
●
Data supply from the line computer should be checked.
821 DP: Set-up and cluster without valid machine data
CAUSE
●
Incorrect data supply from the line computer.
REMEDY
●
Data supply from the line computer should be checked.
822 DP: Error in the data supply from LC
CAUSE
●
Incorrect data supply from the line computer.
REMEDY
●
Data supply from the line computer should be checked.
823 DP: Invalid request from Visiontask
CAUSE
●
Software error in operation DP with vision system
REMEDY
●
Reboot

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 93
824 DP: Fiducial telegram in mixed line not allowed
CAUSE
●
Fiducial telegram sent to SIPLACE from line computer in mixed line.
REMEDY
●
Check configuration.
825 DP: Unknown message received
CAUSE
●
Software error
REMEDY
●
Reboot
826 DP: Error while updating the int. global data
CAUSE
●
Software error
REMEDY
●
Reboot
827 DP: Error while creating int. list for pack. form data
CAUSE
●
Software error
REMEDY
●
Reboot
828 DP: No more storing capacity available
CAUSE
●
Station computer has no more memory capacity left
REMEDY
●
Data too large (set-up, cluster, ....); reboot
829 DP: Error in local communication
CAUSE
●
Software error
REMEDY
●
Reboot
830 DP: Error during equipment cataloging
CAUSE
●
Software error
REMEDY
●
Reboot