00191025-01.pdf - 第724页
SIPLACE 80 S/F /G 20 Index Edition 07/97 from Software Version SR.010.xx 20 - 1 20 Index

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 136
1194 Glue spot check: no evaluation due to low qual.
CAUSE
●
The shape or contrast of the glue spot was not good enough for the glue spot check.
REMEDY
●
Check the gluing needle (defective, dirty).
The glue is leaving threads (check glue temperature)
Color of the glue is not satisfactory (for example, white glue), leading to poor contrast with the glue
scraper roller where the glue spot check is made.
1195 Glue spots too small for calculating volume adaption
CAUSE
●
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
●
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration

SIPLACE 80 S/F/G 20 Index
Edition 07/97 from Software Version SR.010.xx
20 - 1
20 Index

20 Index SIPLACE 80 S/F/G
Edition 07/97 from Software Version SR.010.xx
20 - 2