00191025-01.pdf - 第677页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 90 803 BO: Insufficient memory for postponement (length) CAUSE ● No memory ava ilable. REMEDY ● Re…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 89
796 BO: Text line interrupted at length (character/i)
CAUSE
●
Contents of the text file are faulty.
REMEDY
●
If the error occurs again after error message 704, reset station.
797 BO: Text line interrupted at type (character/i)
CAUSE
●
Contents of the text file are faulty.
REMEDY
●
If the error occurs again after error message 704, reset station.
798 BO: Text line interrupted at name (character/i)
CAUSE
●
Contents of the text file are faulty.
REMEDY
●
If the error occurs again after error message 704, reset station.
799 BO: Unknown state while loading texts (state)
CAUSE
●
System error while loading the texts.
REMEDY
●
Reset station.
800 BO: Text too long (text index/actual length)
CAUSE
●
A text is longer than permitted.
REMEDY
●
If the error occurs again after error message 704, inform Development.
801 BO: Invalid length information (text index/ith char)
CAUSE
●
Contents of the text file are faulty.
REMEDY
●
If the error occurs again after error message 704, reset station.
802 BO: Postponement line full (ident/code)
CAUSE
●
The operator interface is receiving too many jobs and cannot process these.
REMEDY
●
Reset station.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 90
803 BO: Insufficient memory for postponement (length)
CAUSE
●
No memory available.
REMEDY
●
Reset station.
804 BO: POOL cannot be given back (length);
CAUSE
●
A requested memory area can no longer be returned, system error.
REMEDY
●
Reset station.
805 BO: Message cannot be sent (state/code)
CAUSE
●
Error during system call "send" or not enough memory available.
REMEDY
●
Reset station.
806 NF: unexpected input
CAUSE
●
System error
REMEDY
●
If possible, ignore
807 KLKONF: System error during initialization
CAUSE
●
Software error in glueing configuration task
REMEDY
●
Reboot
808 KLKONF: System error during memory request
CAUSE
●
Software error in glueing configuration task during memory request
REMEDY
●
Reboot
809 KLKONF: System error during give back memory
CAUSE
●
Software error in glueing configuration task during give back memory
REMEDY
●
Reboot

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 91
810 KLKONF: System error during send message
CAUSE
●
Software error in glueing configuration task during send message
REMEDY
●
Reboot
811 KLKONF: Incorrect input
CAUSE
●
Software error in glueing configuration task; Incorrect message received
REMEDY
●
Reboot
812 KLKONF: Invalid input data
CAUSE
●
Software error in glueing configuration task; Incorrect data received from data preparation
REMEDY
●
Reboot; get the data organized
813 WARNING: Glue data from file ".ZKL" invalid
CAUSE
●
1. No *.ZKL can be found (with glueing parameters which have not yet been manipulated).
2. Data from "ZKL" incorrect.
REMEDY
●
To 1. Not an error
To 2. Delete *.ZKL, manipulate, then a new *.ZKL will be created.
814 Glueing data cannot be modified
CAUSE
●
Software error
REMEDY
●
Reboot
815 DP: Incorrect operating system call
CAUSE
●
Software error
REMEDY
●
AUT 5V Service or AUT 5 BSM14 (Development) should be notified.
816 DP: No LC command in service without LC
CAUSE
●
Machine in "service without line computer" but all the same command received via IEC bus.
REMEDY
●
Machines and line configuration should be checked.