SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 19
207 Fault in placement stat. during vac. meas.
CAUSE
●
Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing; com-
ponent was not picked up properly; vacuum in the holding circuit too low; vacuum board defective.
REMEDY
●
Fit new nozzle; calibration of the motor control board; check component feed, call SMD Service.
208 End position BERO of centering station not being actuated
CAUSE
●
End position Bero defective or incorrectly set; recuperator spring of the centering station worn out.
REMEDY
●
Fit new Bero, adjust; maintain centering station.
209 Counting error X axis
CAUSE
●
Scales dirty (incremental encoder).
REMEDY
●
Clean scales (incremental encoder).
210 Measurement trigger BERO of centering station not actuated
CAUSE
●
Distance between Bero and actuator flag too great; Bero defective
REMEDY
●
Correct distance to actuator flag; fit new Bero.
211 Counting error Y axis
CAUSE
●
Scales dirty (incremental encoder).
REMEDY
●
Clean scales (incremental encoder).
212 Fault during vacuum measuring in reject position
CAUSE
●
O-ring on the sealing piston damaged.
REMEDY
●
Fit new O-ring to the sealing piston.
213 Timeout during reception from coplanarity
CAUSE
●
Coplanarity module not plugged in
REMEDY
●
Plug in module

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 20
214 Check sum error of answer from coplanarity
CAUSE
●
Error in the response from coplanarity.
REMEDY
●
Check the supply voltage of the coplanarity module check; repeat measurement.
215 Position control of S axis does not work
CAUSE
●
The position control of the axis is not working correctly.
REMEDY
●
Switch off the machine (reset); check axis for stiffness.
216 Position control of X axis does not work
CAUSE
●
The position control of the axis is not working correctly.
REMEDY
●
Switch off the machine (reset); check axis for stiffness.
217 Position control of Y axis does not work
CAUSE
●
The position control of the axis is not working correctly.
REMEDY
●
Switch off the machine (reset); check axis for stiffness.
218 Answer from coplanarity has no STX
CAUSE
●
The first character of the answer from coplanarity is lost.
REMEDY
●
Check supply voltage; check jumper of the coplanarity module; repeat measurement.
219 Coplan.: Communication buffer overflow on MC
CAUSE
●
Too many measurement data for one component
REMEDY
●
Inform AUT 5 V Service or Development AUT 5 BSM 14.
220 Coplanarity cannot execute command
CAUSE
●
Wrong command was sent to the coplanarity module; coplanarity was not initialized
error during execution; package form data erroneous.
REMEDY
●
Switch machine off and back on; respecify set-up; check package form data.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 21
221 Programmed position of X axis outside travel range
CAUSE
●
Error in the local machine data (location fiducials).
REMEDY
●
Check the fiducial data in the machine data.
222 Programmed position of Y axis outside travel range
CAUSE
●
Error in the local machine data (location fiducials).
REMEDY
●
Check the fiducial data in the machine data.
223 Programmed position of D1 axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
224 Programmed position of D2 axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
225 Programmed position of S axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
226 Vacuum of pick-up circuit not within range
CAUSE
●
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
●
Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
●
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
●
Maintain segments; check vacuum; extend limits; check vacuum circuit.