00191025-01.pdf - 第643页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 56 457 Undefined error me ssage CAUSE ● Does not occur REMEDY ● 458 Undefined error me ssage CAUSE…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 55
451 IC head sensor for Z axis does not react
CAUSE
Top Bero of the Z axis of the IC head defective; top Bero of the Z axis of the IC head incorrectly
aligned;
erroneous zero point correction.
REMEDY
Check input top Bero (input is always 0); realign top Bero of the Z axis of the IC head; change zero
point correction.
452 IC head sensor for Z axis is not released at top
CAUSE
Top Bero of the Z axis of the IC head defective.
REMEDY
Check input top Bero (input is always 1).
453 Component could not be placed
CAUSE
After placement by the IC head the component is still at the nozzle.
REMEDY
Vacuum circuit defective; forced air or vacuum cannot be switched off.
454 Component could not be placed. Warning!
CAUSE
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
Check vacuum circuit; check forced air and vacuum of the IC head.
455 Component not on nozzle during placement
CAUSE
After placement by the IC head the component is still at the nozzle.
REMEDY
Vacuum circuit defective; forced air or vacuum cannot be switched off.
456 Component not on nozzle during placement. Warning!
CAUSE
The component could be recognized as placed by the IC head only after the second measurement.
REMEDY
Check vacuum circuit; check forced air and vacuum of the IC head.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 56
457 Undefined error message
CAUSE
Does not occur
REMEDY
458 Undefined error message
CAUSE
Does not occur
REMEDY
459 Coplan.: Memory for group description full
CAUSE
In the set-up there are too many components with coplanarity measurement.
REMEDY
Reduce set-up.
460 Coplan.: Memory for package form description full
CAUSE
In the set-up there are too many components with coplanarity measurement.
REMEDY
Reduce set-up.
461 Programmed position of D axis outside of travel range
CAUSE
Should not occur.
REMEDY
Inform AUT 5 BSM 14 Development.
462 Programmed position of Z axis outside of travel range
CAUSE
Head height, nozzle length erroneous.
REMEDY
Correct head height, nozzle length.
463 IC head D axis does not reach desired position
CAUSE
Motor defective; clamping actuated.
REMEDY
Fit new motor; release clamping and check.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 57
464 IC head Z axis does not reach desired position
CAUSE
Motor defective; Z axis jamming; clamping actuated.
REMEDY
Fit new motor; check Z axis; release clamping and check.
465 IC head D axis disabled
CAUSE
D axis switched off at the axis controller switch.
REMEDY
Switch on D axis at the axis controller.
466 IC head Z axis disabled
CAUSE
Z axis switched off at the axis controller switch.
REMEDY
Switch on Z axis at the axis controller.
467 Gantry distance insufficient. Protective system reacted
CAUSE
Gantries have been moved too close together.
REMEDY
Switch machine off and back on.
468 Component outside of positional tolerance
CAUSE
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
Optimize pick-up; raise positional tolerances in the package form editor.
469 Component outside of positional tolerance
CAUSE
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
Optimize pick-up; raise positional tolerances in the package form editor.
470 Component length outside tolerance
CAUSE
Incorrect component length; tolerances defined are too small.
REMEDY
Raise tolerance; check component description in the package form editor.