00191025-01.pdf - 第658页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 71 560 Error during ope ration nozzle head contr ol SP head CAUSE ● Er ror in pro gram run In the m…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 70
554 Communication between SR and MC interrupted
CAUSE
Hardware fault in a module (M18, M34) or a wiring fault.
REMEDY
Replace modules; check the wiring at the back of the control unit.
555 Option nozzle changer IC head not set
CAUSE
The nozzle-changer was called without this option being set in the line computer.
REMEDY
Configure the nozzle-changer in the line computer.
556 Nozzle type not available
CAUSE
During nozzle changing or pick-up a nozzle type was demanded which lies outside the valid range.
REMEDY
Check the cluster and set-up.
557 Nozzle type not in set-up nozzle changer IC head
CAUSE
The nozzle type required was not included in the nozzle-changer set-up
REMEDY
Modify nozzle-changer set-up.
558 Error during MVS initialization via HS3L
CAUSE
Wiring of HS3L interface faulty; MVS card not inserted correctly in control unit.
REMEDY
Check HS3L wiring; check seating of the MVS card.
559 Data error in MC: Indices for optical centering not O.K.
CAUSE
The job data are inconsistent.
REMEDY
Check the camera records in the REAL.MA file; check the job data (GF data) in the line computer.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 71
560 Error during operation nozzle head control SP head
CAUSE
Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
Notify AUT 5 V Service Department
561 Modify nozzle changer SP head
CAUSE
The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line computer)
erroneous; incorrect sensor system type input at line computer
REMEDY
Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
564 Error during deletion of fiducials in MVS
CAUSE
Cannot occur
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 72
565 Error during loading of fiducials into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version
567 Error while loading coplanarity data into module
CAUSE
Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
Check the SST.ma file; check the MVS Eprom version
569 Limited conveyor position recognition
CAUSE
Conveyor fiducials are outside the travel range of the main axes
REMEDY
Set conveyor up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <Magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
Set magazine full; check the garage in question