00191025-01.pdf - 第692页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 05 904 OPT: No glueing position received CAUSE ● Glue o ptimization received the glueing n umber …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 104
897 DP: Glue identification lines not available
CAUSE
In aktuell.ma the incorrect glue name was specified
REMEDY
Correct the data in aktuell.ma
898 DP: VKL data not available
CAUSE
A glue name specified in aktuell.ma is not available *.VKL file
REMEDY
Correct aktuell.ma and *.VKL file
899 DP: INI data not available
CAUSE
A glue name specified in aktuell.ma is not available as *.INI file
REMEDY
Correct aktuell.ma and *.INI file
900 OPT: Error during data reception
CAUSE
Software error between data preparation and glue optimization
REMEDY
Cluster data should be corrected; reboot
901 OPT: Error during memory request
CAUSE
Software error in glue optimization: no more memory available
REMEDY
Files may be too large; reboot
902 OPT: No memory received
CAUSE
Software error in glue optimization: no more memory available
REMEDY
Files may be too large; reboot
903 OPT: Error during look
CAUSE
Software error in glue optimization
REMEDY
Reboot
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 105
904 OPT: No glueing position received
CAUSE
Glue optimization received the glueing number "zero"
REMEDY
Check data
905 Glueing size not possible with glue available
CAUSE
Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
Glueing size is larger than 20
REMEDY
Check data
907 OPT: Glueing position outside of travel range
CAUSE
Optimization received a position outside the travel range
REMEDY
Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
Board barcode has been sent to line computer; the line computer does not have this barcode in its
list
REMEDY
Wrong board fed in; something wrong with the list in the line computer.
909 DP: Glue type list KLL incorrectly loaded
CAUSE
Faulty data (*.vkl, SIPLACE.KLL) on the hard disk
REMEDY
Check all *.vkl files (including file name in the file)
910 VS: Search for array index not successful
CAUSE
The job file is not consistent
REMEDY
Check the camera records in REAL.MA; check the job data (GF data) in the line computer.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 106
911 OPT: Spacer in contact with glueing point
CAUSE
Glueing points are too close together or their position relative to the spacer is not good.
REMEDY
Reposition the spacer and reoptimize the cluster.
NOTE
The spacer angle must be input in the "Modify system data" menu.
912 DP: axis type incorrect in small gantry mapping data
CAUSE
Incorrect axis type in the RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
913 DP: errors in gantry ident. in small gantry map. data
CAUSE
Incorrect gantry identification in RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
1001 Undefined error message
CAUSE
Error does not occur
REMEDY
1002 Undefined error message
CAUSE
Error does not occur
REMEDY
1003 Undefined error message
CAUSE
Error does not occur
REMEDY