00191025-01.pdf - 第614页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 27 262 Undefined axi s command CAUSE ● Axis boa rd defectiv e; local ma chine dat a incorre ct; err…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 26
255 Undefined error message
CAUSE
Should not occur.
REMEDY
Inform SMD Service.
256 Undefined error number from MVS (ED)
CAUSE
Should not occur.
REMEDY
Inform SMD Service.
257 Undefined error number from MVS (EF)
CAUSE
Should not occur.
REMEDY
Inform SMD Service.
258 Vacuum of the holding circuit is too low
CAUSE
Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
261 Component too large for opt. multiple measurement
CAUSE
The number of measurements determined by the vision system is greater than the maximum permit-
ted number.
REMEDY
Check the package form data.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 27
262 Undefined axis command
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
263 Undefined positioning type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
264 Limit switch actuated
CAUSE
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
Clean scale; call SMD Service.
265 Position outside travel range
CAUSE
Error in the local machine data.
REMEDY
Check positions.
266 Position contains an invalid character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
268 Undefined reference point type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 28
269 Acceleration/deceleration too great
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
270 PCB interrupted due to EMERGENCY STOP
CAUSE
The guard was opened or the EMERGENCY STOP button pressed while placement was in
progress.
REMEDY
Before opening the guard press the STOP switch and wait until the machine stops.
271 Check sum error of coplanarity
CAUSE
Error in the command to the coplanarity.
REMEDY
Repeat measurement; check supply voltage; jumper check.
272 Vision system not providing measure result
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component) .
273 Undefined error number from CRDL (0B)
CAUSE
Should not occur.
REMEDY
274 Fiducial type (fid/ink spot) not correct
CAUSE
Should not occur.
REMEDY
275 VS: Unknown request
CAUSE
Incorrect ICOS software version.
REMEDY
Check eproms and replace if necessary.