00191025-01.pdf - 第650页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 63 504 Current limiter I r.m.s has reac ted CAUSE ● Servo is being subj ected to lim itation, a xis…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 62
497 Software error in coplanarity module; boot
CAUSE
Internal error of the coplanarity module.
REMEDY
Inform AUT 5 V Service.
498 Coplan.: Command Quit sent
CAUSE
Software error
REMEDY
Inform AUT 5 V Service; inform AUT 5 BSM 14 Development.
499 Peak offset: Component outside of search area
CAUSE
Component was not picked up correctly.
REMEDY
Check component description and pick-up position.
500 Peak offset: Evaluation not possible
CAUSE
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
Optimize pick-up; check charge (component).
501 Error in default branch
CAUSE
The format of the measurement results from optical centering cannot be interpreted by the MC soft-
ware.
REMEDY
Check sure that the MVS Eprom version is compatible with the station computer software.
502 MC has received wrong error number
CAUSE
Software error: the error number lies outside the error range
REMEDY
Notify AUT 5 BSM 14 - Development.
503 Flatpack magazine is empty
CAUSE
Last component of a flatpack magazine has been picked up.
REMEDY
Change flatpack magazine.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 63
504 Current limiter I
r.m.s
has reacted
CAUSE
Servo is being subjected to limitation, axis jamming.
REMEDY
Check mechanism for ease of running.
505 Error during RMOS System Call RECV
CAUSE
Software error
REMEDY
Reboot and inform Development.
506 Error during RMOS System Call DALOC
CAUSE
Software error
REMEDY
Reboot and inform Development.
507 Error during RMOS System Call ALOC
CAUSE
Software error
REMEDY
Reboot and inform Development.
508 Error during RMOS System Call LOOK
CAUSE
Software error
REMEDY
Reboot and inform Development.
509 Error during RMOS System Call RIO
CAUSE
Software error
REMEDY
Reboot and inform Development.
510 Error during RMOS System Call CREATEDRIV
CAUSE
Software error
REMEDY
Reboot and inform Development.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 64
511 Error during RMOS System Call MALLOC
CAUSE
Software error
REMEDY
Reboot and inform Development.
512 Incorrect value of state counter
CAUSE
Software error
REMEDY
Reboot
513 Unknown operating state message
CAUSE
Software error
REMEDY
Reboot
514 Illegal operating state
CAUSE
Software error
REMEDY
Reboot
515 SV: Unknown data code
CAUSE
Software error
REMEDY
Inform Development
516 SV: Incorrect data length
CAUSE
Software error
REMEDY
Inform Development
517 Software error: Answer from coplanarity too long
CAUSE
Software error: the answer from coplanarity exceeds the buffer length in the MC
REMEDY
Repeat the coplanarity measurement; notify AUT 5 BSM 14 - Development