00191025-01.pdf - 第611页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 24 242 No PCB on the center conveyor CAUSE ● Transpo rtation on to output conv eyor was s tarted u…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 23
235 Center conveyor light barrier is not released
CAUSE
●
PCB board jamming in the central conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
●
PCB board jamming in the center conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
●
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
●
Check compressed air; adjust back pressure; replace stopper.
238 Stopper jam during retraction
CAUSE
●
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
●
Check compressed air; adjust back pressure; replace stopper.
239 Component description of coplanarity is not complete
CAUSE
●
Package form data erroneous.
REMEDY
●
Check package form data and respecify set-up.
240 Command data format to coplanarity is invalid
CAUSE
●
Package form data, set-up, cluster erroneous.
REMEDY
●
Check and respecify package form data, set-up, cluster.
241 Coplanarity tolerance is zero
CAUSE
●
Coplanarity tolerance (max. component height tolerance) in the set-up for the placement positions of
the circuit image is zero.
REMEDY
●
Increase coplanarity tolerance (max. component height tolerance) and respecify set-up and cluster.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 24
242 No PCB on the center conveyor
CAUSE
●
Transportation onto output conveyor was started under single functions although there is no board
on the center conveyor; sensor in the center conveyor defective.
REMEDY
●
Only start transportation onto the output conveyor under single functions when there is a board on
the center conveyor; fit new sensor.
243 PCB does not reach the output conveyor
CAUSE
●
PCB board jamming in the center conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
244 Center conveyor occupied
CAUSE
●
When the function "Board to center conveyor" started there already was a PCB board on the center
conveyor; sensor defective.
When the belt speed was set the center conveyor was occupied.
REMEDY
●
Remove the PCB board; fit new sensor.
245 Output conveyor occupied
CAUSE
●
When the function "Board to output conveyor" started there already was a PCB board on the output
conveyor; sensor of output conveyor defective.
When the belt speed was set output conveyor was occupied.
REMEDY
●
Remove the PCB board; fit new sensor.
246 BERO of left table side is not activated
CAUSE
●
Bero is not covered.
REMEDY
●
Check Bero.
247 Error in axis programming (left table side)
CAUSE
●
Bero of the left table side defective; axis could not be moved.
REMEDY
●
Check Bero; reboot.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 25
248 BERO of left table side responding constantly
CAUSE
●
Bero constantly covered.
REMEDY
●
Check Bero.
249 Width adjustment at limit switch maximum width
CAUSE
●
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
●
Move width adjustment in other direction; fit new limit switch.
250 Width adjustment at limit switch minimum width
CAUSE
●
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
●
Move width adjustment in other direction; fit new limit switch.
251 PCB on conveyor during width adjustment
CAUSE
●
PCB board on conveyor during width adjustment.
REMEDY
●
Remove the PCB board.
252 Hardware error: software relay for op.voltage defective
CAUSE
●
Relay K5 defective.
REMEDY
●
Replace relay K5.
253 Hardware error: no operating voltage
CAUSE
●
Cover open; start button pressed too briefly.
REMEDY
●
Close cover completely; press start button longer.
254 Hardware error: protective interlocking is defective
CAUSE
●
The protective switch is defective.
REMEDY
●
Replace protective switch.