SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 105
904 OPT: No glueing position received
CAUSE
Glue optimization received the glueing number "zero"
REMEDY
Check data
905 Glueing size not possible with glue available
CAUSE
Glueing size specified by the line computer in this cluster is not possible with the glue set up
REMEDY
Set up glue again
906 OPT: Glueing size received is invalid
CAUSE
Glueing size is larger than 20
REMEDY
Check data
907 OPT: Glueing position outside of travel range
CAUSE
Optimization received a position outside the travel range
REMEDY
Travel range and cluster should be checked
908 Caution: PCB transported through by line computer
CAUSE
Board barcode has been sent to line computer; the line computer does not have this barcode in its
list
REMEDY
Wrong board fed in; something wrong with the list in the line computer.
909 DP: Glue type list KLL incorrectly loaded
CAUSE
Faulty data (*.vkl, SIPLACE.KLL) on the hard disk
REMEDY
Check all *.vkl files (including file name in the file)
910 VS: Search for array index not successful
CAUSE
The job file is not consistent
REMEDY
Check the camera records in REAL.MA; check the job data (GF data) in the line computer.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 106
911 OPT: Spacer in contact with glueing point
CAUSE
Glueing points are too close together or their position relative to the spacer is not good.
REMEDY
Reposition the spacer and reoptimize the cluster.
NOTE
The spacer angle must be input in the "Modify system data" menu.
912 DP: axis type incorrect in small gantry mapping data
CAUSE
Incorrect axis type in the RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
913 DP: errors in gantry ident. in small gantry map. data
CAUSE
Incorrect gantry identification in RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
1001 Undefined error message
CAUSE
Error does not occur
REMEDY
1002 Undefined error message
CAUSE
Error does not occur
REMEDY
1003 Undefined error message
CAUSE
Error does not occur
REMEDY
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 107
1004 Undefined error message
CAUSE
Error does not occur
REMEDY
1005 z axis; GU1: Bero at top does not react
CAUSE
z1 axis is not positioned high enough; Bero defective; z1 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1006 Glue: z axis; GU2: Bero at top does not react
CAUSE
z2 axis is not positioned high enough; Bero defective; z2 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1007 Glue: z axis; GU3: Bero at top does not react
CAUSE
z3 axis is not positioned high enough; Bero defective; z3 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1008 Undefined error message
CAUSE
Error does not occur
REMEDY
1009 Undefined error message
CAUSE
Error does not occur
REMEDY