00191025-01.pdf - 第688页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 01 880 PF data: Error in internal PF list CAUSE ● Softwar e error REMEDY ● AUT 5 B SM 14 Devel op…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 100
873 Set-up data: Unknown sensor system type
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
874 Set-up data: Invalid reference in set-up telegram
CAUSE
●
Faulty set-up telegram from the line computer.
REMEDY
●
Check line computer data.
875 Set-up data: Unknown nozzle changer type
CAUSE
●
Error in set-up telegram from line computer.
REMEDY
●
Check nozzle changer type in the line computer.
876 Set-up data: Unknown track type in set-up telegram
CAUSE
●
Faulty set-up telegram from the line computer.
REMEDY
●
Check line computer data.
877 Set-up data: Error while writing WPC set-up
CAUSE
●
It was not possible to access the hard disk.
REMEDY
●
Check hard disk (consistency, storage capacity)
878 PF data: first PF number = 0; PF telegram faulty
CAUSE
●
Transfer a zero into the PF telegram as PF number.
REMEDY
●
Check line computer data.
879 PF data: Unknown sensor system type
CAUSE
●
This type of sensor system does not exist for this machine type
REMEDY
●
Check line computer data.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 101
880 PF data: Error in internal PF list
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
881 PF data: Number of PFs in telegram too large
CAUSE
●
Max. number of the package form descriptions in the PF telegram from the line computers has been
exceeded.
REMEDY
●
Cannot occur.
882 PF data: Model No. from group not in description
CAUSE
●
A model number has been specified in the group description which does not exist with this PF.
REMEDY
●
Check line computer data.
883 PF data: No reference to this PF in set-up
CAUSE
●
PF which is not required has been received from the line computer.
REMEDY
●
Check line computer data.
884 PF data: Sensor system type No. not in PF telegram
CAUSE
●
A sensor system type no. is specified in the PF telegram which is invalid for this machine type.
REMEDY
●
Check line computer data.
885 PF data: PF telegram not received from LC
CAUSE
●
PF required was not received from the line computer.
REMEDY
●
Check line computer data, feasibility
886 PF data: Deletion telegram for PF not available
CAUSE
●
Telegram from the line computer: deletion of PF which is not available.
REMEDY
●
Check line computer data.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 102
887 MK-data: Incorrect length of binary share
CAUSE
●
Fiducial telegram from the line computer or fiducial file faulty.
REMEDY
●
Check line computer data.
888 DP: First part of telegram missing
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.
889 DP: Last part of telegram missing
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.
890 DP: Telegram incomplete
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.
891 DP: Invalid character in telegram
CAUSE
●
Telegram from the line computer mutilated (IEC communication); local file mutilated by incorrect
editing; hard disk defective; interface versions line computer and station computer incompatible.
REMEDY
●
Check station computer / line computer software versions.
IEC - Check cables. Check file.