SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 93 824 DP : Fiducial telegram in mix ed line not allowed CAUSE ● Fiducia l telegr am sent to SIPLAC…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 92
817 DP: Set-up without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
818 DP: Cluster without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
819 DP: Package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
820 DP: Delete package form without valid set-up data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
821 DP: Set-up and cluster without valid machine data
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
822 DP: Error in the data supply from LC
CAUSE
Incorrect data supply from the line computer.
REMEDY
Data supply from the line computer should be checked.
823 DP: Invalid request from Visiontask
CAUSE
Software error in operation DP with vision system
REMEDY
Reboot
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 93
824 DP: Fiducial telegram in mixed line not allowed
CAUSE
Fiducial telegram sent to SIPLACE from line computer in mixed line.
REMEDY
Check configuration.
825 DP: Unknown message received
CAUSE
Software error
REMEDY
Reboot
826 DP: Error while updating the int. global data
CAUSE
Software error
REMEDY
Reboot
827 DP: Error while creating int. list for pack. form data
CAUSE
Software error
REMEDY
Reboot
828 DP: No more storing capacity available
CAUSE
Station computer has no more memory capacity left
REMEDY
Data too large (set-up, cluster, ....); reboot
829 DP: Error in local communication
CAUSE
Software error
REMEDY
Reboot
830 DP: Error during equipment cataloging
CAUSE
Software error
REMEDY
Reboot
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 94
831 DP: Dynam. equipment cannot be generated
CAUSE
Software error
REMEDY
Reboot
832 DP: Conversion job without input data
CAUSE
Software error
REMEDY
Reboot
833 DP: Error during conversion of MC structures
CAUSE
Software error
REMEDY
Reboot
834 DP: Error while writing MC structures on hard disk
CAUSE
Data could not be written to hard disk.
REMEDY
Hard disk and hardware should be checked.
835 DP: Transfer to MC not possible
CAUSE
Software error
REMEDY
Reboot
836 DP: Missing file name for PF
CAUSE
PF could not be found
REMEDY
Check data
837 DP: Cannot open package form file
CAUSE
An error occurred while the file was being read
REMEDY
Hard disk and file should be checked