00191025-01.pdf - 第672页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 85 769 Barcode too long, cut off! CAUSE ● The ma ximum pe rmissible l ength of the board barc ode i…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 84
763 BO: Error dur. memory request f. text pool (no./length)
CAUSE
●
System error, not enough memory available.
REMEDY
●
764 BO: Cannot open text file
CAUSE
●
Text file not found.
REMEDY
●
The name of the text file is in the file C:\Texte\SITXT.CFG. If this file does not exist, the software
must be reinstalled.
765 BO: Text index too large (text index/max index)
CAUSE
●
A text in the text file is too large.
REMEDY
●
Ignore but inform AUT 5 BSM 14 Development.
766 BO: Text index defined twice (text index/i. )
CAUSE
●
On loading texts, double text indices were detected. Loading is repeated.
REMEDY
●
Ignore, but inform AUT 5 BSM 14 Development.
767 PCB barcode: incorrect format
CAUSE
●
The machine has not identified the board barcode received from the barcode reader.
REMEDY
●
Input manually via the keyboard or try again. Once placement of the current board is complete the
error menu will drop down.
768 No data received from PCB barcode reader
CAUSE
●
PCB barcode reader not responding.
REMEDY
●
Check PCB barcode reader.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 85
769 Barcode too long, cut off!
CAUSE
●
The maximum permissible length of the board barcode is 25 characters, of the component 20 char-
acters; a longer barcode was received, but was cut short.
REMEDY
●
The machine carries on working with the shortened barcode.
770 BL: unexpected input
CAUSE
●
System error
REMEDY
●
If possible, ignore.
771 VS: Communication between SR and MC defective
CAUSE
●
Software error
REMEDY
●
Reboot, if occurs repeatedly inform Development.
772 EH: received CODE unknown
CAUSE
●
Incorrect message to task EH.
REMEDY
●
If possible, ignore.
773 EH: received IDENT unknown
CAUSE
●
Incorrect message to task EH.
REMEDY
●
If possible, ignore.
774 EH: MC sending too many error messages (> F_FM_MAX)
CAUSE
●
Error handling can receive a maximum of 200 error messages at the same time from the machine
controller.
REMEDY
●
The error messages > 200 are discarded.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 86
775 Data preparation : cannot save current MA data
CAUSE
●
File "AKTUELL.MA" cannot be saved.
REMEDY
●
Check hard disk, check slide-in module, when rebooting update AKTUELL.MA, it may be that the
hard disk is full.
776 AKT: Error during system call ALOC
CAUSE
●
No memory allocated to Task T_AKT.
REMEDY
●
Reboot.
777 AKT: Incorrect input
CAUSE
●
Task AKT has received unknown message.
REMEDY
●
If possible, ignore, otherwise reboot.
778 AKT: Wrong data from data preparation
CAUSE
●
Data preparation sending incorrect "AKTUELL.MA" format to task T_AKT.
REMEDY
●
System error, reboot.
779 Undefined operation with and without LC
CAUSE
●
The station computer receives a message from the line computer, but it was input at station com-
puter as "without LC".
REMEDY
●
Input mode "with LC" at the station computer.
780 Undefined error in LC reception
CAUSE
●
Error when receiving via IEC bus.
REMEDY
●
Reboot.
781 No memory available
CAUSE
●
Memory in station computer is fragmented.
REMEDY
●
Reboot.