00191025-01.pdf - 第659页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 72 565 Error during loading of fiduc ials into MVS CAUSE ● Fiducial data from th e line co mputer …

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 71
560 Error during operation nozzle head control SP head
CAUSE
●
Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
●
Notify AUT 5 V Service Department
561 Modify nozzle changer SP head
CAUSE
●
The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
●
Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
●
Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line computer)
erroneous; incorrect sensor system type input at line computer
REMEDY
●
Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
●
Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
●
Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
564 Error during deletion of fiducials in MVS
CAUSE
●
Cannot occur
REMEDY
●

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 72
565 Error during loading of fiducials into MVS
CAUSE
●
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
●
Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
●
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
●
Delete fiducial data and teach them again; check MVS Eprom version
567 Error while loading coplanarity data into module
CAUSE
●
Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
●
Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
●
Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
●
Check the SST.ma file; check the MVS Eprom version
569 Limited conveyor position recognition
CAUSE
●
Conveyor fiducials are outside the travel range of the main axes
REMEDY
●
Set conveyor up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <Magazine/garage>:
CAUSE
●
Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
●
Set magazine full; check the garage in question

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 73
571 Nozzle not returned to <Magazine/garage>:
CAUSE
●
Garage indicated of the magazine in question is already occupied; x, y or z positions are not correct
(real.ma)
REMEDY
●
Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <Type/for segment>:
CAUSE
●
Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
●
Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <Type/from segment>:
CAUSE
●
Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
●
Nozzle is discarded into the rejects tray
574 Conveyor position recognition not possible
CAUSE
●
Conveyor fiducials are outside the travel range of the main axes
REMEDY
●
Set up the conveyor for locations which are within the travel range of the board camera
575 Incorrect centering device setting for component concerned
CAUSE
●
Incorrect entry in the line computer GF editor.
REMEDY
●
Change the processing data for the package form in the line computer GF editor.
578 Nozzle not ejected into rejects box
CAUSE
●
The component or the nozzle is jamming at the rejects box.
The rejects box is full.
REMEDY
●
Use the SITEST program to record the x, y and z nozzle positions.
Remove the obstacle or empty the rejects box.