00191025-01.pdf - 第659页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 72 565 Error during loading of fiduc ials into MVS CAUSE ● Fiducial data from th e line co mputer …

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 71
560 Error during operation nozzle head control SP head
CAUSE
Error in program run
In the menu "General errors" the following applies to Info1:
Info1 = 1 Setting up not necessary
Info1 = 2 Magazine no. invalid
Info1 = 3 Segment no. invalid
Info1 = 4 Garage not found
REMEDY
Notify AUT 5 V Service Department
561 Modify nozzle changer SP head
CAUSE
The corresponding nozzle type has not been set up in the nozzle-changer
REMEDY
Modify nozzle-changer set-up in accordance with required specification and confirm in the menu
with the return key.
562 Error while loading GF geom. description data into MVS
CAUSE
Camera records in real.ma are erroneous; old MVS Eprom version; GF description (line computer)
erroneous; incorrect sensor system type input at line computer
REMEDY
Check camera records (real.ma); check Eprom MVS version
563 Error while loading GF meas. conditions data into MVS
CAUSE
Erroneous manipulation of measuring conditions (test vision system / component; “Rucksack” file
from line computer faulty (part of GF file which can be manipulated)
REMEDY
Undo manipulation; delete “Rucksack” file in the line computer or assign new GF number
564 Error during deletion of fiducials in MVS
CAUSE
Cannot occur
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 72
565 Error during loading of fiducials into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version
566 Error while loading fiducial centering param. into MVS
CAUSE
Fiducial data from the line computer or station computer disk are erroneous; incorrect MVS Eprom
version
REMEDY
Delete fiducial data and teach them again; check MVS Eprom version
567 Error while loading coplanarity data into module
CAUSE
Coplanarity has been selected for BGAs; erroneous GF description in the line computer
REMEDY
Deactivate coplanarity option; check GF description
568 Error while loading parameter pool into MVS
CAUSE
Erroneous data in the SST.ma file; incorrect MVS Eprom version
REMEDY
Check the SST.ma file; check the MVS Eprom version
569 Limited conveyor position recognition
CAUSE
Conveyor fiducials are outside the travel range of the main axes
REMEDY
Set conveyor up for locations which lie within the travel range of the board camera
570 Nozzle not picked up from <Magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already empty; x, y or z positions are not correct
(real.ma)
REMEDY
Set magazine full; check the garage in question
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 73
571 Nozzle not returned to <Magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already occupied; x, y or z positions are not correct
(real.ma)
REMEDY
Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <Type/for segment>:
CAUSE
Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <Type/from segment>:
CAUSE
Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
Nozzle is discarded into the rejects tray
574 Conveyor position recognition not possible
CAUSE
Conveyor fiducials are outside the travel range of the main axes
REMEDY
Set up the conveyor for locations which are within the travel range of the board camera
575 Incorrect centering device setting for component concerned
CAUSE
Incorrect entry in the line computer GF editor.
REMEDY
Change the processing data for the package form in the line computer GF editor.
578 Nozzle not ejected into rejects box
CAUSE
The component or the nozzle is jamming at the rejects box.
The rejects box is full.
REMEDY
Use the SITEST program to record the x, y and z nozzle positions.