00191025-01.pdf - 第598页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 11 125 Coplanarity: clamping of z axis does not work CAUSE ● Clampin g reacts to o slow; clam ping …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 10
102 Quality too low during optical centering
CAUSE
Parameters for optical centering erroneous.
REMEDY
Check the package form in the components manipulator.
103 Spacing of a pin group out of tolerance
CAUSE
Bent terminal pin; pitch error limit defined too small.
REMEDY
Check components; increase pitch error limit in the package form editor.
104 Component angle outside of tolerance
CAUSE
Angular positioning deviation of the component on the nozzle too great; angular positioning toler-
ance defined too small.
REMEDY
Improve pick-up; increase angular positioning tolerance.
121 Peak offset: no result
CAUSE
Component terminal pin bent.
REMEDY
Check quality of the components.
122 Coplanarity module cannot be initialized
CAUSE
Coplanarity module not plugged in; configuration jumper incorrectly set
REMEDY
Plug in module; correct jumper.
123 Coplan.: Data value outside of range
CAUSE
Error in cluster or set-up: PF file faulty
REMEDY
Check data for coplanarity in cluster and set-up; check PF data.
124 Vacuum reduction at placem. stat. too slow
CAUSE
During placement of a component the vacuum does not reduce fast enough;
forced air not present; forced air defective.
REMEDY
Check forced air; check forced air valve.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 11
125 Coplanarity: clamping of z axis does not work
CAUSE
Clamping reacts too slow; clamping is defective.
REMEDY
Operate clamping repeatedly; check clamping.
126 Unknown telegram to table
CAUSE
Obsolete
TISCH.HEX
file.
REMEDY
Update
TISCH.HEX
file.
127 Caution: Filling level of rej. comp. receptacle 70%
CAUSE
Does not occur
REMEDY
128 Receptacle of rejected componentes full
CAUSE
Does not occur
REMEDY
129 Communication table-feeder interrupted
CAUSE
Since the last booting, the connection with the conveyor has been interrupted; the conveyor is not
plugged in; cable is defective.
REMEDY
Plug in the conveyor; check the cable.
130 Communication table-feeder disturbed
CAUSE
Communication between table and conveyor is interrupted from time to time; the cable is defective;
the conveyor has been unplugged.
REMEDY
Plug in the conveyor; check the cable and plug.
131 Software-Operation in feeder disturbed
CAUSE
Software error
REMEDY
Notify AUT 5 BSM 14 - Development.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 12
132 Foil torn
CAUSE
The cover foil is torn; the foil removal force has been set incorrectly; the conveyor is defective.
REMEDY
Repair the foil; adjust removal springs; replace the conveyor.
133 Foil not removed
CAUSE
The cover foil is not being stripped off; the foil removal force has been set incorrectly; the conveyor is
defective.
REMEDY
Pull off the foil by hand; set removal spring
134 Transport in feeder disturbed
CAUSE
Tape backing up; the conveyor is defective
REMEDY
Remove tape back-up; replace the conveyor
135 Caution: Belt end
CAUSE
Does not occur
REMEDY
136 Nozzle type not available in changer magazine SP
CAUSE
Not used
REMEDY
137 Not enough garages in changer magazine for nozzle return. SP
CAUSE
Nozzles should be returned
With optical garage check: all garages were checked with the board camera and are occupied.
Without optical garage check: there are not enough empty garages available for the nozzles to be
returned.
REMEDY
Takes place automatically: all nozzles which could not be returned are rejected.