19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 6 30 BERO SZ2 not released (close segment) CAUSE ● Proximi ty switch de fective; component ja mmed…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 5
23 End position BERO of centering station not being activated
CAUSE
●
Bero defective; mechanism of the centering station stiff; recuperator spring worn out.
REMEDY
●
Fit new Bero; maintain centering station; call SMD Service.
25 Error in programming of the CRDL
CAUSE
●
CRDL tester configured in software, but tester itself not present; communication interrupted at the
CRDL tester; interrupt wiring of MC CRDL tester defective.
REMEDY
●
Set corresponding parameters (CRDL tester) to non-active.
26 Measurement trigger BERO of centering station is not released
CAUSE
●
Bero defective; mechanism of the centering station stiff; actuating plate bent; motor control board
defective.
REMEDY
●
Fit new Bero; maintain centering station; call SMD Service.
27 Component cannot be rejected
CAUSE
●
Positive airflow valve not switching, cable break at the valve
REMEDY
●
Check and repair wiring
28 The nozzle in the reject position is clogged
CAUSE
●
Nozzle worn, air duct of the segment blocked
REMEDY
●
Fit new nozzle, clean or replace segment
29 BERO SZ2 not released (open segment)
CAUSE
●
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
●
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 6
30 BERO SZ2 not released (close segment)
CAUSE
●
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
●
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
38 Star axis does not reach setpoint position ?
CAUSE
●
Segment slit position incorrect at insertion; component jammed between toothed belt and toothed
belt pulley; speed was input incorrectly in the MA_DATA; power supply interrupted; motor defective;
belt tension not correct; segment cam is rubbing against the Z axis.
REMEDY
●
Insert segment with correct slit position; remove component; correct speed value correspondingly;
check plugged connections; replace motor, adjust toothed belt tension, carry out calibration of the
servo board; slacken cam leaf springs of segment and realign cam.
43 Component not at nozzle after pick-up
CAUSE
●
Suction face of the nozzle damaged; nozzle too small; component was not supplied.
REMEDY
●
Fit new nozzle; check component feed.
44 Component not at nozzle before placement
CAUSE
●
Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing; com-
ponent was not picked up properly; vacuum in the holding circuit too low; vacuum board defective.
REMEDY
●
Fit new nozzle; carry out calibration of the motor control board; check component feed, call SMD
Service.
48 Results of vac measurement of pick-up & reject station inversed
CAUSE
●
Vacuum circuit defective; compressed air bad.
REMEDY
●
Check vacuum circuit; check compressed air.
50 SZ1 only succeeded on the second attempt
CAUSE
●
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration of
the motor control board not optimal.
REMEDY
●
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 7
52 BERO SZ2 not being actuated
CAUSE
●
Bad plugged connection of the screwdriver at the gantry board; motor control board
defective.
REMEDY
●
Check plugged connections; fit new motor control board, carry out calibration of the axes.
53 SZ2 only succeeded on second attempt
CAUSE
●
Stiffness in the gearwheel/pinion of the screwdriver; stiffness in the pusher movement; calibration of
the motor control board not optimal.
REMEDY
●
Maintain screwdriver; maintain segment; carry out calibration of the motor control board.
54 BERO SZ1 not being actuated
CAUSE
●
Bad plugged connection of the screwdriver at the gantry board; motor control board defective.
REMEDY
●
Check plugged connections; fit new motor control board, carry out calibration of the axes.
59 X axis does not reach setpoint position
CAUSE
●
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
●
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
60 Y axis does not reach setpoint position
CAUSE
●
Mechanism jamming; toothed belt parted; drive motor with tacho defective; calibration of the axis
incorrect.
REMEDY
●
Check mechanism; fit new toothed belt; fit new motor with tacho; carry out axis calibration.
61 Z axis does not reach setpoint position
CAUSE
●
Cam disk in incorrect position at zero pulse; motor defective; z axis jamming.
REMEDY
●
Fit cam disk in correct rotational position; redetermine zero point correction; replace motor; carry out
axis calibration; fit spare placement head.