SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 21
221 Programmed position of X axis outside travel range
CAUSE
●
Error in the local machine data (location fiducials).
REMEDY
●
Check the fiducial data in the machine data.
222 Programmed position of Y axis outside travel range
CAUSE
●
Error in the local machine data (location fiducials).
REMEDY
●
Check the fiducial data in the machine data.
223 Programmed position of D1 axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
224 Programmed position of D2 axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
225 Programmed position of S axis outside travel range
CAUSE
●
Programming error, should not occur.
REMEDY
●
226 Vacuum of pick-up circuit not within range
CAUSE
●
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
●
Maintain segments; check vacuum; extend limits; check vacuum circuit.
227 Vacuum of reject circuit not within range
CAUSE
●
Segments dirty; vacuum not working properly; limits specified too low; vacuum circuit defective.
REMEDY
●
Maintain segments; check vacuum; extend limits; check vacuum circuit.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 22
228 Interface signals to the preceding station incorrect
CAUSE
●
Interface line not connected; cable defective; interface boards defective.
REMEDY
●
Check signal path, replace defective assemblies.
229 The input conveyor light barrier is not covered
CAUSE
●
PCB board was removed while program was executing; PCB board jamming; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
230 The input conveyor light barrier is not released
CAUSE
●
PCB board jamming; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
231 No PCB on the input conveyor
CAUSE
●
The PCB board was removed while being transported onto the central conveyor; sensor defective.
REMEDY
●
Under the menu "Transportation error" continue placement, place board on input conveyor; fit new
sensor.
232 The lifting table cannot be moved downwards
CAUSE
●
Beros defective; cutout triggered.
REMEDY
●
fit new Beros; close lifting table cutout.
233 Command to coplanarity is not complete
CAUSE
●
Package form data, set-up erroneous.
REMEDY
●
Re-assign set-up, repeat measurement.
234 The lifting table cannot be moved upwards
CAUSE
●
Beros defective; cutout triggered.
REMEDY
●
Fit new Beros; close lifting table cutout.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 23
235 Center conveyor light barrier is not released
CAUSE
●
PCB board jamming in the central conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
236 PCB does not reach the center conveyor
CAUSE
●
PCB board jamming in the center conveyor; sensor defective.
REMEDY
●
Correct the jamming; fit new sensor.
237 Stopper jam during extension
CAUSE
●
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
●
Check compressed air; adjust back pressure; replace stopper.
238 Stopper jam during retraction
CAUSE
●
Compressed air lacking; back pressure too high; stopper defective.
REMEDY
●
Check compressed air; adjust back pressure; replace stopper.
239 Component description of coplanarity is not complete
CAUSE
●
Package form data erroneous.
REMEDY
●
Check package form data and respecify set-up.
240 Command data format to coplanarity is invalid
CAUSE
●
Package form data, set-up, cluster erroneous.
REMEDY
●
Check and respecify package form data, set-up, cluster.
241 Coplanarity tolerance is zero
CAUSE
●
Coplanarity tolerance (max. component height tolerance) in the set-up for the placement positions of
the circuit image is zero.
REMEDY
●
Increase coplanarity tolerance (max. component height tolerance) and respecify set-up and cluster.