00191025-01.pdf - 第613页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 26 255 Undefined error me ssage CAUSE ● Shoul d not occur. REMEDY ● Info rm SMD Servi ce. 256 Unde…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 25
248 BERO of left table side responding constantly
CAUSE
Bero constantly covered.
REMEDY
Check Bero.
249 Width adjustment at limit switch maximum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.
250 Width adjustment at limit switch minimum width
CAUSE
Width adjustment moved up to the limit switch; limit switch defective.
REMEDY
Move width adjustment in other direction; fit new limit switch.
251 PCB on conveyor during width adjustment
CAUSE
PCB board on conveyor during width adjustment.
REMEDY
Remove the PCB board.
252 Hardware error: software relay for op.voltage defective
CAUSE
Relay K5 defective.
REMEDY
Replace relay K5.
253 Hardware error: no operating voltage
CAUSE
Cover open; start button pressed too briefly.
REMEDY
Close cover completely; press start button longer.
254 Hardware error: protective interlocking is defective
CAUSE
The protective switch is defective.
REMEDY
Replace protective switch.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 26
255 Undefined error message
CAUSE
Should not occur.
REMEDY
Inform SMD Service.
256 Undefined error number from MVS (ED)
CAUSE
Should not occur.
REMEDY
Inform SMD Service.
257 Undefined error number from MVS (EF)
CAUSE
Should not occur.
REMEDY
Inform SMD Service.
258 Vacuum of the holding circuit is too low
CAUSE
Segments leaky; compressed air too low; vacuum circuit defective.
REMEDY
Check segments; adjust compressed air; replace vacuum circuit.
259 Axis command invalid at present
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
260 Illegal bit combination in handshake byte
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
261 Component too large for opt. multiple measurement
CAUSE
The number of measurements determined by the vision system is greater than the maximum permit-
ted number.
REMEDY
Check the package form data.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 27
262 Undefined axis command
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
263 Undefined positioning type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
264 Limit switch actuated
CAUSE
Limit switch defective; axis miscounting and moving up against limit switch.
REMEDY
Clean scale; call SMD Service.
265 Position outside travel range
CAUSE
Error in the local machine data.
REMEDY
Check positions.
266 Position contains an invalid character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
267 Position contains an invalid prefix character
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.
268 Undefined reference point type
CAUSE
Axis board defective; local machine data incorrect; error should not occur.
REMEDY
Fit new axis board.