SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 47
398 Coplan.: Row not available
CAUSE
●
Package form description erroneous; software error.
REMEDY
●
Check and respecify package form description; inform Aut 5 BSM 14 Development.
399 Program loss of table or trolley control
CAUSE
●
Battery reserve in the component table is not working.
REMEDY
●
Fit new battery to component table.
400 RAM of trolley control defective
CAUSE
●
Hardware error in the component table
REMEDY
●
If error keeps recurring, reset station; if resetting does not work, replace component table.
401 New nozzle configuration is required
CAUSE
●
New cluster with different nozzle configuration
REMEDY
●
If no nozzle changer is present, apply new nozzle configuration manually to placement head.
402 Pulse is not okay
CAUSE
●
Connection of pulse output to pulse input defective.
REMEDY
●
Check pulse output and pulse input
403 Coplan.: Too many pins measured
CAUSE
●
Measurement erroneous or incorrect component.
REMEDY
●
Repeat measurement.
404 Fault during vacuum measuring in reject position
CAUSE
●
Nozzle worn.
REMEDY
●
Fit new nozzle.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 48
405 Fault during vacuum measuring in reject position
CAUSE
●
Proximity switch defective; component jammed between screwdriver and segment;
motor of the screwdriver defective.
REMEDY
●
Replace proximity switch, adjust sensing distance; remove component; check toothing for damage;
replace motor with hub, carry out calibration on the motor control board.
406 Axis does not find the correct zero pulse
CAUSE
●
Measurement head incorrectly set
REMEDY
●
Check zero pulse at the measurement head (moving scale) of the longitudinal measurement sys-
tem. Adjust or replace measurement head.
407 Communication with table disturbed
CAUSE
●
Timeout during request to the component table controller.
REMEDY
●
Check cabling.
408 Table has received unknown command
CAUSE
●
Obsolete TISCH.HEX file.
REMEDY
●
Update TISCH.HEX file.
409 Undefined error message
CAUSE
●
Should not occur.
REMEDY
●
410 Telegram to coplanarity too long
CAUSE
●
Package form description of the component includes too much information.
REMEDY
●
Check and respecify package form data; the package form is too large and cannot be processed.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 49
411 FM_ERSTER_FEHLER
CAUSE
●
Error during testing, significance varies.
REMEDY
●
412 FM_LETZTER_FEHLER
CAUSE
●
Error during testing, significance varies.
REMEDY
●
413 FM_FEHLER_1
CAUSE
●
Error during testing, significance varies.
REMEDY
●
414 FM_FEHLER_2
CAUSE
●
Error during testing, significance varies.
REMEDY
●
415 FM_FEHLER_3
CAUSE
●
Error during testing, significance varies.
REMEDY
●
416 FM_FEHLER_4
CAUSE
●
Error during testing, significance varies.
REMEDY
●
417 FM_FEHLER_5
CAUSE
●
Error during testing, significance varies.
REMEDY
●