00191025-01.pdf - 第661页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 74 694 Nozzle length deviates excessively from stipulated length CAUSE ● No nozz le present. The n…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 73
571 Nozzle not returned to <Magazine/garage>:
CAUSE
Garage indicated of the magazine in question is already occupied; x, y or z positions are not correct
(real.ma)
REMEDY
Nozzle is discarded into rejects tray; check the garage in question
572 Nozzle type not available <Type/for segment>:
CAUSE
Nozzle type displayed has not been set up or the corresponding magazine is empty
REMEDY
Fill magazine or insert by hand and confirm in the menu
573 Nozzle type not returnable <Type/from segment>:
CAUSE
Magazine displayed has not been set up for this nozzle type or the magazine is full
REMEDY
Nozzle is discarded into the rejects tray
574 Conveyor position recognition not possible
CAUSE
Conveyor fiducials are outside the travel range of the main axes
REMEDY
Set up the conveyor for locations which are within the travel range of the board camera
575 Incorrect centering device setting for component concerned
CAUSE
Incorrect entry in the line computer GF editor.
REMEDY
Change the processing data for the package form in the line computer GF editor.
578 Nozzle not ejected into rejects box
CAUSE
The component or the nozzle is jamming at the rejects box.
The rejects box is full.
REMEDY
Use the SITEST program to record the x, y and z nozzle positions.
Remove the obstacle or empty the rejects box.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 74
694 Nozzle length deviates excessively from stipulated length
CAUSE
No nozzle present.
The nozzle is seated incorrectly.
The wrong nozzle type has been set up.
REMEDY
Make sure the head is fitted with the correct nozzle.
Check the seating of the nozzle.
696 Warning: Break to DP1-axis
CAUSE
Internal program run error when the DP1 axis is overshooting.
REMEDY
Confirm the error message.
If this error occurs frequently, please notify AUT 5 V Service
697 Warning: Break to DP2-axis
CAUSE
Internal program run error when the DP1 axis is overshooting.
REMEDY
Confirm the error message.
If this error occurs frequently, please notify AUT 5 V Service
698 Error during break to DP1-axis: boot!
CAUSE
It is not possible to confirm error message 696 with respect to the internal program run error.
REMEDY
Reboot the station. Notify AUT 5 Development.
699 Error during break to DP2-axis: boot!
CAUSE
It is not possible to confirm error message 697 with respect to the internal program run error.
REMEDY
Reboot the station. Notify AUT 5 Development.
701 BO: Info received is not a message (ident/code)
CAUSE
BO has received a message which is not actually classified as a message. The details (ident code)
concern the contents of the message. These values are given in (Info1/Info2).
REMEDY
Write down error message giving the complete error message and under what conditions the error
occurred. With the machine at standstill, reset the machine.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 75
702 BO: Mouse code not implemented (mouse code)
CAUSE
BO has received an unknown message.
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
703 BO: CODE received unknown (code/state)
CAUSE
BO has received unknown or unexpected message.
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
704 Initialization of text table not possible at 1st trial
CAUSE
There is an error in the text table (text too long, for example)
REMEDY
It is not necessary to stop operation. Please notify AUT 5 BSM 14 - Development.
705 BO: Unknown element type in dialogue field (type)
CAUSE
Error in the data of the BO
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
706 BO: ID type unknown in menu (menuid_type)
CAUSE
Error in the data of the BO
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
707 CRDL 1 without mechanical centering configured
CAUSE
Despite the CRDL tester, the mechanical centering station has not been configured (tester without
mechanical centering station is not possible)
REMEDY
Correct the configuration in the line computer for this station.