SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 17
158 Limit switch of width adjustment for minimum width actuated
CAUSE
Conveyor belt width has been set too small
REMEDY
Increase conveyor belt width
159 Limit switch of width adjustment for maximum width actuated
CAUSE
Conveyor belt width has been set too large
REMEDY
Reduce conveyor belt width
160 Bero not found during conveyor belt width check
CAUSE
Conveyor belt bero is defective or set incorrectly
REMEDY
Check bero
161 Bero covered before conveyor belt width check
CAUSE
Conveyor belt bero responds before the actual position (gantry) is reached
REMEDY
Adjust bero
162 WPC must be moved from refill position
CAUSE
WPC is in the refill position
REMEDY
The operator should quit the refill position in the "Refill" "Location1" menu.
163 Conveyor belt width out of travel range
CAUSE
The conveyor width detected lies outside of the possible range of values.
The sensing distance of the bero has been set too high.
The bero is defective.
REMEDY
Use the SITEST program to re-register the 100mm board and run width measurement again.
The sensing distance of the bero has been set too high.
Replace bero.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 18
201 Track empty, optical centering incorrect
CAUSE
3 optical measuring errors with component from one track; set up for incorrect component.
Incorrect angle has been input for the component in the feeder.
REMEDY
Check components feed; fill up empty track and reset track.
check set-up data.
202 Track empty, measure value outside tol.
CAUSE
3 electrical measurement errors with component from one track
REMEDY
Check components feed; fill up empty track and reset track.
203 Track set empty by operator
CAUSE
Under the menu "Refill" track set to empty.
REMEDY
Reset track in the menu "Refill".
204 Z axis cannot be moved upwards
CAUSE
When the start button pressed Z axis not in top position.
REMEDY
Check servo, push Z axis upwards by hand.
205 BERO for Z axis top position not released
CAUSE
Sensing distance too great; Bero defective; cam disk not tightened up correctly; z zero point correc-
tion value incorrect; counting error.
REMEDY
Adjust sensing distance; replace Bero; tighten up cam disk; redetermine z zero point correction; fit
new motor/tacho/encoder; carry out axis calibration.
206 Fault in pick-up station during vac. meas.
CAUSE
Suction face of the nozzle damaged; nozzle too small; component was not supplied.
REMEDY
Fit new nozzle; check component feed.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 19
207 Fault in placement stat. during vac. meas.
CAUSE
Suction face of the nozzle damaged; nozzle too small; jaws of the centering station bouncing; com-
ponent was not picked up properly; vacuum in the holding circuit too low; vacuum board defective.
REMEDY
Fit new nozzle; calibration of the motor control board; check component feed, call SMD Service.
208 End position BERO of centering station not being actuated
CAUSE
End position Bero defective or incorrectly set; recuperator spring of the centering station worn out.
REMEDY
Fit new Bero, adjust; maintain centering station.
209 Counting error X axis
CAUSE
Scales dirty (incremental encoder).
REMEDY
Clean scales (incremental encoder).
210 Measurement trigger BERO of centering station not actuated
CAUSE
Distance between Bero and actuator flag too great; Bero defective
REMEDY
Correct distance to actuator flag; fit new Bero.
211 Counting error Y axis
CAUSE
Scales dirty (incremental encoder).
REMEDY
Clean scales (incremental encoder).
212 Fault during vacuum measuring in reject position
CAUSE
O-ring on the sealing piston damaged.
REMEDY
Fit new O-ring to the sealing piston.
213 Timeout during reception from coplanarity
CAUSE
Coplanarity module not plugged in
REMEDY
Plug in module