19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 62 497 Software error in coplanarity module; boot CAUSE ● Internal error of the copla narity modu …

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 61
490 Coplan.: Placement level not found
CAUSE
●
Placement level could not be determined.
REMEDY
●
Repeat measurement.
491 Undefined error message
CAUSE
●
Should not occur.
REMEDY
●
492 Coplanarity module defective; replace and boot
CAUSE
●
Internal error of the coplanarity module.
REMEDY
●
Inform AUT 5 V Service.
493 Coplanarity module defective; replace and boot
CAUSE
●
Internal error of the coplanarity module.
REMEDY
●
Inform AUT 5 V Service.
494 Coplanarity module defective; replace and boot
CAUSE
●
Internal error of the coplanarity module.
REMEDY
●
Inform AUT 5 V Service.
495 Coplanarity module defective; replace and boot
CAUSE
●
Internal error of the coplanarity module.
REMEDY
●
Inform AUT 5 V Service.
496 Coplanarity module defective; replace and boot
CAUSE
●
Internal error of the coplanarity module.
REMEDY
●
Inform AUT 5 V Service.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 62
497 Software error in coplanarity module; boot
CAUSE
●
Internal error of the coplanarity module.
REMEDY
●
Inform AUT 5 V Service.
498 Coplan.: Command Quit sent
CAUSE
●
Software error
REMEDY
●
Inform AUT 5 V Service; inform AUT 5 BSM 14 Development.
499 Peak offset: Component outside of search area
CAUSE
●
Component was not picked up correctly.
REMEDY
●
Check component description and pick-up position.
500 Peak offset: Evaluation not possible
CAUSE
●
No component at the nozzle; component outside tolerance; not enough image information to provide
measurement result.
REMEDY
●
Optimize pick-up; check charge (component).
501 Error in default branch
CAUSE
●
The format of the measurement results from optical centering cannot be interpreted by the MC soft-
ware.
REMEDY
●
Check sure that the MVS Eprom version is compatible with the station computer software.
502 MC has received wrong error number
CAUSE
●
Software error: the error number lies outside the error range
REMEDY
●
Notify AUT 5 BSM 14 - Development.
503 Flatpack magazine is empty
CAUSE
●
Last component of a flatpack magazine has been picked up.
REMEDY
●
Change flatpack magazine.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 63
504 Current limiter I
r.m.s
has reacted
CAUSE
●
Servo is being subjected to limitation, axis jamming.
REMEDY
●
Check mechanism for ease of running.
505 Error during RMOS System Call RECV
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
506 Error during RMOS System Call DALOC
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
507 Error during RMOS System Call ALOC
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
508 Error during RMOS System Call LOOK
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
509 Error during RMOS System Call RIO
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.
510 Error during RMOS System Call CREATEDRIV
CAUSE
●
Software error
REMEDY
●
Reboot and inform Development.