00191025-01.pdf - 第723页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 136 1194 Glue spot check: no evaluation due to low qua l. CAUSE ● The sh ape or contras t of the g…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 135
1188 Glue spot check: error during meas. description generation
CAUSE
Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
Check data
1189 Glue spot check: error during measurement description loading
CAUSE
Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system
1191 Glue spot check: measurements start error
CAUSE
Transmission error with MVS vision system
REMEDY
Check vision system
1192 Glue spot check: error in measurement results
CAUSE
Possibly incorrect Eprom version; otherwise software error
REMEDY
Check Eprom version
1193 Glue spots too large for calculating volume adaption
CAUSE
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 136
1194 Glue spot check: no evaluation due to low qual.
CAUSE
The shape or contrast of the glue spot was not good enough for the glue spot check.
REMEDY
Check the gluing needle (defective, dirty).
The glue is leaving threads (check glue temperature)
Color of the glue is not satisfactory (for example, white glue), leading to poor contrast with the glue
scraper roller where the glue spot check is made.
1195 Glue spots too small for calculating volume adaption
CAUSE
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration