SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 35 1188 Glue spot check: error during meas . description generation CAUSE ● Target di ameter o f …

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 134
1181 Z-axis, GU2: While raising, Bero not activated
CAUSE
●
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1182 Z-axis, GU3: While raising, Bero not activated
CAUSE
●
Z axis is not moving upwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1183 Z-axis, GU1: When axis at bottom, Bero not released
CAUSE
●
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1184 Z-axis, GU2: When axis at bottom, Bero not released
CAUSE
●
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1185 Z-axis, GU3: When axis at bottom, Bero not released
CAUSE
●
Z axis is not moving downwards (sluggish); the bero is defective or set incorrectly
REMEDY
●
Check the mechanism; check the bero; check the incremental transducer.
1186 Pressure build-up faulty
CAUSE
●
The glue cartridge is missing; the compressed air supply to the dispenser unit is inadequate;
the valve (actuation) is defective
REMEDY
●
Insert cartridge; check the compressed air supply, hoses, valve
1187 Pressure reduction faulty
CAUSE
●
The venting valve (actuation) is defective
REMEDY
●
Check the valve and hoses

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 135
1188 Glue spot check: error during meas. description generation
CAUSE
●
Target diameter of the glue spots in the VKL file are outside the permitted range (0 < or < 3 mm)
Camera data (MA data) conversion factor pixels => µm erroneous
REMEDY
●
Check data
1189 Glue spot check: error during measurement description loading
CAUSE
●
Transmission error with the MVS vision system; possibly incorrect Eprom version
REMEDY
●
Check Eprom version
1190 Glue spot check: error during visualization of results
CAUSE
●
Transmission error with MVS vision system
REMEDY
●
Check vision system
1191 Glue spot check: measurements start error
CAUSE
●
Transmission error with MVS vision system
REMEDY
●
Check vision system
1192 Glue spot check: error in measurement results
CAUSE
●
Possibly incorrect Eprom version; otherwise software error
REMEDY
●
Check Eprom version
1193 Glue spots too large for calculating volume adaption
CAUSE
●
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
●
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 136
1194 Glue spot check: no evaluation due to low qual.
CAUSE
●
The shape or contrast of the glue spot was not good enough for the glue spot check.
REMEDY
●
Check the gluing needle (defective, dirty).
The glue is leaving threads (check glue temperature)
Color of the glue is not satisfactory (for example, white glue), leading to poor contrast with the glue
scraper roller where the glue spot check is made.
1195 Glue spots too small for calculating volume adaption
CAUSE
●
The size of glue spots is outside the control range for volume adaption (-5....+5); incorrect gluing sta-
tion configuration
REMEDY
●
Check process parameters: nozzle diameter, spacer, temperature;
check gluing station configuration