00191025-01.pdf - 第663页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 76 708 CRDL 2 without mechanical ce ntering configured CAUSE ● Despite the CRDL test er, the me ch…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 75
702 BO: Mouse code not implemented (mouse code)
CAUSE
BO has received an unknown message.
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
703 BO: CODE received unknown (code/state)
CAUSE
BO has received unknown or unexpected message.
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
704 Initialization of text table not possible at 1st trial
CAUSE
There is an error in the text table (text too long, for example)
REMEDY
It is not necessary to stop operation. Please notify AUT 5 BSM 14 - Development.
705 BO: Unknown element type in dialogue field (type)
CAUSE
Error in the data of the BO
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
706 BO: ID type unknown in menu (menuid_type)
CAUSE
Error in the data of the BO
REMEDY
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
707 CRDL 1 without mechanical centering configured
CAUSE
Despite the CRDL tester, the mechanical centering station has not been configured (tester without
mechanical centering station is not possible)
REMEDY
Correct the configuration in the line computer for this station.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 76
708 CRDL 2 without mechanical centering configured
CAUSE
Despite the CRDL tester, the mechanical centering station has not been configured (tester without
mechanical centering station is not possible)
REMEDY
Correct the configuration in the line computer for this station.
709 BO: Event flag ID unknown (flag id)
CAUSE
System error during system call SVC-Look for event flag group of the keyboard task
REMEDY
When the machine is at a standstill, reset the machine.
710 BO: Error in RIO. HSFS_XREAD (sts)
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
711 BO: 1st status byte HSFS_XREAD (status[0])
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
712 BO: Error in RIO POLL_XBUF (sts)
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
713 BO: 1st status byte POLL_XBUF (status[0])
CAUSE
System error during keyboard input.
REMEDY
When the machine is at a standstill, reset the machine.
714 NF: no memory available
CAUSE
System error
REMEDY
Reboot
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 77
715 BO: Error in pause (sts)
CAUSE
System error during system call PAUSE.
REMEDY
When the machine is at a standstill, reset the machine.
716 BO Barcode terminator not found
CAUSE
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
Reread the barcode. If this does not work, check the barcode header and terminator.
717 BO: 1st character of barcode terminator not found
CAUSE
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
Reread the barcode. If this does not work, check the barcode header and terminator.
718 VS: Unknown message code
CAUSE
Software error
REMEDY
Inform Development; possibly reboot.
719 VS: Error during system call look
CAUSE
Software error
REMEDY
Inform Development; possibly reboot.
720 VS: File could not be opened
CAUSE
File does not exist in the station computer
REMEDY
Reinstall software
721 VS: Error in fiducial data
CAUSE
Fiducial data erroneous; obsolete ICOS version
REMEDY
Reset ICOS, update eproms