00191025-01.pdf - 第663页
19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 76 708 CRDL 2 without mechanical ce ntering configured CAUSE ● Despite the CRDL test er, the me ch…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 75
702 BO: Mouse code not implemented (mouse code)
CAUSE
●
BO has received an unknown message.
REMEDY
●
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
703 BO: CODE received unknown (code/state)
CAUSE
●
BO has received unknown or unexpected message.
REMEDY
●
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
704 Initialization of text table not possible at 1st trial
CAUSE
●
There is an error in the text table (text too long, for example)
REMEDY
●
It is not necessary to stop operation. Please notify AUT 5 BSM 14 - Development.
705 BO: Unknown element type in dialogue field (type)
CAUSE
●
Error in the data of the BO
REMEDY
●
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
706 BO: ID type unknown in menu (menuid_type)
CAUSE
●
Error in the data of the BO
REMEDY
●
Write down error message giving the complete error message and stating under what conditions the
error occurred. With the machine at standstill, reset the machine.
707 CRDL 1 without mechanical centering configured
CAUSE
●
Despite the CRDL tester, the mechanical centering station has not been configured (tester without
mechanical centering station is not possible)
REMEDY
●
Correct the configuration in the line computer for this station.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 76
708 CRDL 2 without mechanical centering configured
CAUSE
●
Despite the CRDL tester, the mechanical centering station has not been configured (tester without
mechanical centering station is not possible)
REMEDY
●
Correct the configuration in the line computer for this station.
709 BO: Event flag ID unknown (flag id)
CAUSE
●
System error during system call SVC-Look for event flag group of the keyboard task
REMEDY
●
When the machine is at a standstill, reset the machine.
710 BO: Error in RIO. HSFS_XREAD (sts)
CAUSE
●
System error during keyboard input.
REMEDY
●
When the machine is at a standstill, reset the machine.
711 BO: 1st status byte HSFS_XREAD (status[0])
CAUSE
●
System error during keyboard input.
REMEDY
●
When the machine is at a standstill, reset the machine.
712 BO: Error in RIO POLL_XBUF (sts)
CAUSE
●
System error during keyboard input.
REMEDY
●
When the machine is at a standstill, reset the machine.
713 BO: 1st status byte POLL_XBUF (status[0])
CAUSE
●
System error during keyboard input.
REMEDY
●
When the machine is at a standstill, reset the machine.
714 NF: no memory available
CAUSE
●
System error
REMEDY
●
Reboot

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 77
715 BO: Error in pause (sts)
CAUSE
●
System error during system call PAUSE.
REMEDY
●
When the machine is at a standstill, reset the machine.
716 BO Barcode terminator not found
CAUSE
●
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
●
Reread the barcode. If this does not work, check the barcode header and terminator.
717 BO: 1st character of barcode terminator not found
CAUSE
●
The terminator is missing after the barcode header, barcode at the barcode pen not recognized.
REMEDY
●
Reread the barcode. If this does not work, check the barcode header and terminator.
718 VS: Unknown message code
CAUSE
●
Software error
REMEDY
●
Inform Development; possibly reboot.
719 VS: Error during system call look
CAUSE
●
Software error
REMEDY
●
Inform Development; possibly reboot.
720 VS: File could not be opened
CAUSE
●
File does not exist in the station computer
REMEDY
●
Reinstall software
721 VS: Error in fiducial data
CAUSE
●
Fiducial data erroneous; obsolete ICOS version
REMEDY
●
Reset ICOS, update eproms