00191025-01.pdf - 第668页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 81 743 LRS: Interface or drive r not found CAUSE ● Does not occur REMEDY ● 744 LRS: Command not in …

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 80
736 GK: Error in local machine data
CAUSE
There are no real or current machine data on the hard disk; the machine data cannot be converted
due to a structure error.
REMEDY
Write the MA data onto the hard disk properly.
737 GK: Error in machine data
CAUSE
The MA data (ideal) coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
738 GK: Error in set-up data
CAUSE
The set-up data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
739 GK: Error in cluster data
CAUSE
The cluster data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
740 GK: Error in fiducial data
CAUSE
The fiducial data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
741 GK: Error in package form data
CAUSE
The package form data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
742 LRS: Timeout during transmission to line computer
CAUSE
Released through IEC bus
REMEDY
Reboot
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 81
743 LRS: Interface or driver not found
CAUSE
Does not occur
REMEDY
744 LRS: Command not in command list
CAUSE
LR SEND incorrect command received
REMEDY
If possible, ignore.
745 LRS: Conversion is not possible
CAUSE
Could not convert data for line computer telegrams SABR/SBES.
REMEDY
No
746 LRS: No communication with line computer
CAUSE
IEC bus is "blocked"
REMEDY
Reboot station and line computers.
747 DP: Data limits exceeded
CAUSE
Incorrect date input
REMEDY
Correct input date
748 DP: required equipment unknown
CAUSE
Possibly the TASKS.CFG file has been changed, or there is a software fault
REMEDY
Reboot with the supplied version of TASKS.CFG ; if necessary, notify AUT 5 BSM 14
Development department
749 No PCB barcode read
CAUSE
Barcode reader has been activated but barcode was not recognized
REMEDY
Make sure the barcode type is correct; make sure the mechanical distance is correct
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 82
750 Data preparation : internal error
CAUSE
Not possible to write to station computer hard disk.
REMEDY
Check disk; disk full?; files write-protected ? (check *.MA, *.GF, *.NU, *.RU)
751 Data preparation : run error
CAUSE
If there was previously an error in the placement data (MK/GF/RU/NU files) all other telegrams com-
ing from the line computer will be discarded and in each case a message generated.
REMEDY
Reboot station (a great deal of specialist knowledge is required for precise identification of this fault).
752 Data preparation : error in machine data
CAUSE
It was not possible to convert the MA data (files AKTUELL.MA, REAL.MA, IDEAL.MA, RASTER.P1,
RASTER.P2).
REMEDY
Check the hard disk for bad clusters with the DOS program using the CHKDSK command; reinstall
machine data (files) onto the hard disk.
753 Data preparation : error in cluster data
CAUSE
It was not possible to convert the NU data.
REMEDY
The line computer has generated a faulty cluster, check data in line computer.
754 Data preparation : error in set-up data
CAUSE
It was not possible to convert the RU data.
REMEDY
The line computer has generated a faulty set-up, check data in line computer.
755 Data preparation : error in package form data
CAUSE
GF could not be converted.
REMEDY
Check GF in the line computer.