SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 81
743 LRS: Interface or driver not found
CAUSE
●
Does not occur
REMEDY
●
744 LRS: Command not in command list
CAUSE
●
LR SEND incorrect command received
REMEDY
●
If possible, ignore.
745 LRS: Conversion is not possible
CAUSE
●
Could not convert data for line computer telegrams SABR/SBES.
REMEDY
●
No
746 LRS: No communication with line computer
CAUSE
●
IEC bus is "blocked"
REMEDY
●
Reboot station and line computers.
747 DP: Data limits exceeded
CAUSE
●
Incorrect date input
REMEDY
●
Correct input date
748 DP: required equipment unknown
CAUSE
●
Possibly the TASKS.CFG file has been changed, or there is a software fault
REMEDY
●
Reboot with the supplied version of TASKS.CFG ; if necessary, notify AUT 5 BSM 14
Development department
749 No PCB barcode read
CAUSE
●
Barcode reader has been activated but barcode was not recognized
REMEDY
●
Make sure the barcode type is correct; make sure the mechanical distance is correct

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 82
750 Data preparation : internal error
CAUSE
●
Not possible to write to station computer hard disk.
REMEDY
●
Check disk; disk full?; files write-protected ? (check *.MA, *.GF, *.NU, *.RU)
751 Data preparation : run error
CAUSE
●
If there was previously an error in the placement data (MK/GF/RU/NU files) all other telegrams com-
ing from the line computer will be discarded and in each case a message generated.
REMEDY
●
Reboot station (a great deal of specialist knowledge is required for precise identification of this fault).
752 Data preparation : error in machine data
CAUSE
●
It was not possible to convert the MA data (files AKTUELL.MA, REAL.MA, IDEAL.MA, RASTER.P1,
RASTER.P2).
REMEDY
●
Check the hard disk for bad clusters with the DOS program using the CHKDSK command; reinstall
machine data (files) onto the hard disk.
753 Data preparation : error in cluster data
CAUSE
●
It was not possible to convert the NU data.
REMEDY
●
The line computer has generated a faulty cluster, check data in line computer.
754 Data preparation : error in set-up data
CAUSE
●
It was not possible to convert the RU data.
REMEDY
●
The line computer has generated a faulty set-up, check data in line computer.
755 Data preparation : error in package form data
CAUSE
●
GF could not be converted.
REMEDY
●
Check GF in the line computer.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 83
756 Data preparation : error in fiducial data
CAUSE
●
MK could not be converted.
REMEDY
●
If this occurs only with a pure SIPLACE line (with MVS) it is best simply to reteach the MK.
757 Data preparation : error in fiducial list
CAUSE
●
Does not occur.
REMEDY
●
758 LR: Error reading telegram
CAUSE
●
Separators or value fields in the line computer telegram are incorrect or overrun.
REMEDY
●
Check hard disk of the station (MS-DOS CHKDSK); reboot.
759 LR: Error in telegram output
CAUSE
●
Does not occur
REMEDY
●
760 LR: Error during telegram treatment
CAUSE
●
Does not occur.
REMEDY
●
761 LR: No memory, task stopped
CAUSE
●
Memory of the station is not fragmented.
REMEDY
●
Reboot station.
762 VS: Maximal gradient number of fiducial profile exceeded
CAUSE
●
Fiducial structure with poor contrast value as background; horizontal / vertical fiducial profile which
contains more than 100 gradients which reach 20% of maximum gradients.
REMEDY
●
Reduce template field, select another fiducial structure.