SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 57 464 IC head Z axis does not reach desired positio n CAUSE ● Motor d efective; Z axis jamm ing; c…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 56
457 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
458 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
459 Coplan.: Memory for group description full
CAUSE
●
In the set-up there are too many components with coplanarity measurement.
REMEDY
●
Reduce set-up.
460 Coplan.: Memory for package form description full
CAUSE
●
In the set-up there are too many components with coplanarity measurement.
REMEDY
●
Reduce set-up.
461 Programmed position of D axis outside of travel range
CAUSE
●
Should not occur.
REMEDY
●
Inform AUT 5 BSM 14 Development.
462 Programmed position of Z axis outside of travel range
CAUSE
●
Head height, nozzle length erroneous.
REMEDY
●
Correct head height, nozzle length.
463 IC head D axis does not reach desired position
CAUSE
●
Motor defective; clamping actuated.
REMEDY
●
Fit new motor; release clamping and check.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 57
464 IC head Z axis does not reach desired position
CAUSE
●
Motor defective; Z axis jamming; clamping actuated.
REMEDY
●
Fit new motor; check Z axis; release clamping and check.
465 IC head D axis disabled
CAUSE
●
D axis switched off at the axis controller switch.
REMEDY
●
Switch on D axis at the axis controller.
466 IC head Z axis disabled
CAUSE
●
Z axis switched off at the axis controller switch.
REMEDY
●
Switch on Z axis at the axis controller.
467 Gantry distance insufficient. Protective system reacted
CAUSE
●
Gantries have been moved too close together.
REMEDY
●
Switch machine off and back on.
468 Component outside of positional tolerance
CAUSE
●
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
●
Optimize pick-up; raise positional tolerances in the package form editor.
469 Component outside of positional tolerance
CAUSE
●
Pick-up not accurate enough; positional tolerances entered in the package form editor are too small.
REMEDY
●
Optimize pick-up; raise positional tolerances in the package form editor.
470 Component length outside tolerance
CAUSE
●
Incorrect component length; tolerances defined are too small.
REMEDY
●
Raise tolerance; check component description in the package form editor.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 58
471 Component width outside tolerance
CAUSE
●
Incorrect component length; tolerances defined are too small.
REMEDY
●
Raise tolerance; check component description in the package form editor.
472 VS: Pointer to text table not initialized
CAUSE
●
Component is not in focus during coplanarity measurement.
REMEDY
●
Check the focussing during coplanarity measurement; check the IC head z axis clamping
473 Temporary drop in pressure
CAUSE
●
The compressed air failed during the placement process, the current PCB board is aborted.
REMEDY
●
Check compressed air feed; check compressed air sensor.
474 Second gantry in travel range
CAUSE
●
While teaching the fiducials (80S), the operator moved the gantries towards each other.
REMEDY
●
Move the second gantry out of the travel range of the first gantry.
475 Communication with wafflepack changer faulty
CAUSE
●
Interface line to the wafflepack changer defective or not correctly connected; power supply to the
wafflepack changer defective.
REMEDY
●
Check interface cable; check power supply.
476 IC head vacuum of pick-up circle not in valid range
CAUSE
●
Nozzle dirty; vacuum cannot be switched on; permissible vacuum limit value for open nozzle errone-
ous.
REMEDY
●
Clean nozzle; check vacuum output and vacuum valve; correct vacuum limit value for open nozzle.