19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 100 873 Set -up data: Unk nown senso r system type CAUSE ● Soft ware e rror REMEDY ● AUT 5 B SM 14…

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 99
866 Clust. data: Number fiducials or passpoint to large
CAUSE
●
Cluster in the line computer contains too many fiducials or passpoints.
REMEDY
●
Cluster should be checked in the line computer; feasibility.
867 Clust. data: Invalid X/Y offset 0 in individual circuit
CAUSE
●
Error in the line computer telegram; offset must not be 0.
REMEDY
●
Cluster should be checked in the line computer; feasibility.
868 Clust. data: Invalid location for machine type
CAUSE
●
Error in the cluster telegram
REMEDY
●
Cluster and set-up should be checked in the line computer; feasibility
869 Clust. data: Incorrect reference in placement options
CAUSE
●
Incorrect reference in the placement positions.
REMEDY
●
Check line computer data.
870 Set-up data: Error during conversion of tracks
CAUSE
●
Error during conversion of tracks.
REMEDY
●
Check line computer data.
871 Set-up data: Missing track chain
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
872 Set-up data: Invalid location for machine type
CAUSE
●
Faulty set-up telegram from the line computer
REMEDY
●
Set-up should be checked; feasibility.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 100
873 Set-up data: Unknown sensor system type
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
874 Set-up data: Invalid reference in set-up telegram
CAUSE
●
Faulty set-up telegram from the line computer.
REMEDY
●
Check line computer data.
875 Set-up data: Unknown nozzle changer type
CAUSE
●
Error in set-up telegram from line computer.
REMEDY
●
Check nozzle changer type in the line computer.
876 Set-up data: Unknown track type in set-up telegram
CAUSE
●
Faulty set-up telegram from the line computer.
REMEDY
●
Check line computer data.
877 Set-up data: Error while writing WPC set-up
CAUSE
●
It was not possible to access the hard disk.
REMEDY
●
Check hard disk (consistency, storage capacity)
878 PF data: first PF number = 0; PF telegram faulty
CAUSE
●
Transfer a zero into the PF telegram as PF number.
REMEDY
●
Check line computer data.
879 PF data: Unknown sensor system type
CAUSE
●
This type of sensor system does not exist for this machine type
REMEDY
●
Check line computer data.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 101
880 PF data: Error in internal PF list
CAUSE
●
Software error
REMEDY
●
AUT 5 BSM 14 Development should be notified.
881 PF data: Number of PFs in telegram too large
CAUSE
●
Max. number of the package form descriptions in the PF telegram from the line computers has been
exceeded.
REMEDY
●
Cannot occur.
882 PF data: Model No. from group not in description
CAUSE
●
A model number has been specified in the group description which does not exist with this PF.
REMEDY
●
Check line computer data.
883 PF data: No reference to this PF in set-up
CAUSE
●
PF which is not required has been received from the line computer.
REMEDY
●
Check line computer data.
884 PF data: Sensor system type No. not in PF telegram
CAUSE
●
A sensor system type no. is specified in the PF telegram which is invalid for this machine type.
REMEDY
●
Check line computer data.
885 PF data: PF telegram not received from LC
CAUSE
●
PF required was not received from the line computer.
REMEDY
●
Check line computer data, feasibility
886 PF data: Deletion telegram for PF not available
CAUSE
●
Telegram from the line computer: deletion of PF which is not available.
REMEDY
●
Check line computer data.