00191025-01.pdf - 第694页

SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 07 1004 Undefined error me ssage CAUSE ● Er ror d oes n ot oc cur REMEDY ● 1005 z axis; GU1: Bero…

100%1 / 736
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 106
911 OPT: Spacer in contact with glueing point
CAUSE
Glueing points are too close together or their position relative to the spacer is not good.
REMEDY
Reposition the spacer and reoptimize the cluster.
NOTE
The spacer angle must be input in the "Modify system data" menu.
912 DP: axis type incorrect in small gantry mapping data
CAUSE
Incorrect axis type in the RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
913 DP: errors in gantry ident. in small gantry map. data
CAUSE
Incorrect gantry identification in RASTER.K1 file (mapping data for glueing station for small gantries)
REMEDY
Make the necessary correction in the machine file RASTER.K1 (axis type).
1001 Undefined error message
CAUSE
Error does not occur
REMEDY
1002 Undefined error message
CAUSE
Error does not occur
REMEDY
1003 Undefined error message
CAUSE
Error does not occur
REMEDY
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 107
1004 Undefined error message
CAUSE
Error does not occur
REMEDY
1005 z axis; GU1: Bero at top does not react
CAUSE
z1 axis is not positioned high enough; Bero defective; z1 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1006 Glue: z axis; GU2: Bero at top does not react
CAUSE
z2 axis is not positioned high enough; Bero defective; z2 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1007 Glue: z axis; GU3: Bero at top does not react
CAUSE
z3 axis is not positioned high enough; Bero defective; z3 axis is jamming
motor, controller, servo-amplifier defective.
REMEDY
Check the components just mentioned.
1008 Undefined error message
CAUSE
Error does not occur
REMEDY
1009 Undefined error message
CAUSE
Error does not occur
REMEDY
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 108
1010 Glue: z axis; GU1: cannot be moved any further upwards
CAUSE
When the start button is pressed the z12 axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the z1 axis upwards by hand
1011 Glue: z axis; GU2: cannot be moved any further upwards
CAUSE
When the start button is pressed the z2 axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the z2 axis upwards by hand
1012 Glue: z axis; GU3: cannot be moved any further upwards
CAUSE
When the start button is pressed the z3 axis is below the minimum position
REMEDY
The servo-amplifier should be checked; slide the z3 axis upwards by hand
1013 xk axis: Position outside of travel range
CAUSE
Not used
REMEDY
1014 yk axis: Position outside of travel range
CAUSE
Not used
REMEDY
1015 z axis; GU1: Position outside of travel range
CAUSE
Not used
REMEDY
1016 z axis; GU2: Position outside of travel range
CAUSE
Not used
REMEDY