SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 59 477 Nozzle av ailable on IC head CAUSE ● Accordi ng to the software configurat ion there is alre…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 58
471 Component width outside tolerance
CAUSE
●
Incorrect component length; tolerances defined are too small.
REMEDY
●
Raise tolerance; check component description in the package form editor.
472 VS: Pointer to text table not initialized
CAUSE
●
Component is not in focus during coplanarity measurement.
REMEDY
●
Check the focussing during coplanarity measurement; check the IC head z axis clamping
473 Temporary drop in pressure
CAUSE
●
The compressed air failed during the placement process, the current PCB board is aborted.
REMEDY
●
Check compressed air feed; check compressed air sensor.
474 Second gantry in travel range
CAUSE
●
While teaching the fiducials (80S), the operator moved the gantries towards each other.
REMEDY
●
Move the second gantry out of the travel range of the first gantry.
475 Communication with wafflepack changer faulty
CAUSE
●
Interface line to the wafflepack changer defective or not correctly connected; power supply to the
wafflepack changer defective.
REMEDY
●
Check interface cable; check power supply.
476 IC head vacuum of pick-up circle not in valid range
CAUSE
●
Nozzle dirty; vacuum cannot be switched on; permissible vacuum limit value for open nozzle errone-
ous.
REMEDY
●
Clean nozzle; check vacuum output and vacuum valve; correct vacuum limit value for open nozzle.

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 59
477 Nozzle available on IC head
CAUSE
●
According to the software configuration there is already a nozzle at the head. This message appears
when an attempt is still made to start the pick-up procedure.
REMEDY
●
If there does not happen to be a nozzle at the head, set up the nozzle specified by the configuration
by hand.
478 Deviation position Z-axis at nozzle changer IC head
CAUSE
●
Z axis has gone beyond or not reached its desired position (MA data); the z axis is jamming
the nozzle is already at the head at pick-up.
REMEDY
●
Check the x, y and z positions; make sure the axis can move freely.
479 Deviation rotation D axis pick up nozzle IC head
CAUSE
●
The d axis is rotating with standstill check as far as the stop. If the actual position (angular position at
the stop) deviates from the desired position (MA data) by more than 15 degrees in either the positive
or the negative direction, this message will appear.
REMEDY
●
Remeasurement and inputting into MA data.
480 Deviation rotation D axis return nozzle IC head
CAUSE
●
The d axis is rotating with standstill check as far as the stop. If the actual position (angular position at
the stop) deviates from the desired position (MA data) by more than 15 degrees in either the positive
or the negative direction, this message will appear.
REMEDY
●
Remeasurement and inputting into MA data.
481 Nozzle not available at nozzle changer IC head
CAUSE
●
A nozzle is being requested which is not in the nozzle changer.
REMEDY
●
If request by machine: check set-up.
If input by operator: correct incorrect input.
482 Modify nozzle changer IC head
CAUSE
●
A new assignment in the nozzle changer IC head is being called for by the line computer.
REMEDY
●
Set up new assignment and acknowledge.

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 60
483 Undefined error message
CAUSE
●
Does not occur
REMEDY
●
484 Coplan.: Division by zero
CAUSE
●
Placement level could not be determined.
REMEDY
●
Repeat measurement.
485 Undefined error message
CAUSE
●
Should not occur
REMEDY
●
486 Coplan.: Component outside of measuring range
CAUSE
●
Component not in focus during coplanarity measurement.
REMEDY
●
Check focus of coplanarity; check clamping of z axis IC head.
487 Coplan.: One pin of component missing
CAUSE
●
Focusing of coplanarity measurement incorrect; component defective.
REMEDY
●
Check focusing; repeat measurement.
488 Coplan.: Measuring on one pin finished
CAUSE
●
Focusing of coplanarity measurement incorrect; component defective.
REMEDY
●
Check focus; repeat measurement.
489 Coplan.: Pin outside of coplan. position tolerance
CAUSE
●
Pin bent; component defective.
REMEDY
●
Repeat measurement with new component.