00191025-01.pdf - 第653页

19 Error Messages S IPLACE 80S/F/G User’s Manual 19.1 Error Mess ages Edition 12/96 from Software Vers ion SR.009.xx 19 - 66 525 WPC: No tray availa ble. CAUSE ● Soft ware e rror REMEDY ● Reboot 526 WPC: Sent s et-up con…

100%1 / 736
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 65
518 SV: Unknown message code from other MC
CAUSE
Software error
REMEDY
Inform Development
519 SV: Unknown message code from station computer
CAUSE
Software error
REMEDY
Inform Development
520 Unknown data code in MC1 during data exchange
CAUSE
Software error
REMEDY
If there are problems after this, reset station, inform Development.
521 Software error in SGL Functions
CAUSE
Incorrect message to single function (Info1) operator error during transition to single function or fatal
error handling ( start button not pressed )
REMEDY
Possibly rebooting
522 Syntax error in command to component table
CAUSE
Software error; interface cable reversed.
REMEDY
Reboot; connect interface cable correctly.
523 Command not executed, component table not referred
CAUSE
Power failure while component carriage moving.
REMEDY
Check power supply and Inform SMD Service.
524 Command not executed, component table in refill position
CAUSE
Software error
REMEDY
Reboot
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 66
525 WPC: No tray available.
CAUSE
Software error
REMEDY
Reboot
526 WPC: Sent set-up contains errors.
CAUSE
Software error
REMEDY
Reboot
527 Feeder rail of bulk case feeder not installed
CAUSE
The feeder rail is not installed on the bulk case feeder
REMEDY
Install feeder rail on bulk case feeder
528 Undefined error number of component table (Code 45)
529 Undefined error number of component table (Code 46)
530 Undefined error number of component table (Code 47)
531 Undefined error number of component table (Code 48)
532 Undefined error number of component table (Code 49)
533 Data loss in component table (defective battery)
CAUSE
Backup battery flat or defective; Controller A18 defective.
REMEDY
Replace battery; fit new A18 and Inform SMD Service.
534 WPC: Fault in feed axis (servo or axis card).
CAUSE
Axis board of the feed axis defective; servo of the feed axis defective.
REMEDY
Fit new axis board or servo board and inform SMD Service.
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 67
535 WPC: Feed axis at limit switch
CAUSE
Feed axis at the limit switch; limit switch defective.
REMEDY
Push feed axis away from limit switch; fit new limit switch.
536 WPC: Axis error of feed axis
CAUSE
Undefined reference point or type of positioning; undefined axis command; position outside the
travel range.
REMEDY
Reboot; inform SMD Service.
537 WPC: Feed axis servo released.
CAUSE
Servo disabled at the axis board.
REMEDY
Switch servo back on at the axis board.
538 WPC: Error in jaw position
CAUSE
At the zero point position the reference Bero of the feed axis is not actuated; incorrect zero point cor-
rection; Bero defective.
REMEDY
Correct zero point correction; replace Bero.
539 WPC: Fault in lifting axis (servo or axis card)
CAUSE
Axis board of the lifting axis defective; Servo of the lifting axis defective.
REMEDY
Fit new axis board or servo board and inform SMD Service.
540 WPC: Lifting axis at limit switch
CAUSE
Lifting axis at the limit switch; limit switch defective.
REMEDY
Release the brake of the lifting axis and push lifting axis away from limit switch; fit new limit switch.