00191025-01.pdf - 第712页
SIPLACE 80S/F/G User’s Manual 19 Error Message s Edition 12/96 from S oftware Version SR.009.xx 19.1 Error Messages 19 - 1 25 1120 X -axis error: Reference error CAUSE ● Invali d referenc e point type i n the mac hine da…

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 124
1113 X axis error: incorrect preceding sign
CAUSE
●
Program error; should not occur
REMEDY
●
1114 Y axis error: incorrect preceding sign
CAUSE
●
Program error; should not occur
REMEDY
●
1115 xk axis error: incorrect preceding sign
CAUSE
●
Program error; should not occur
REMEDY
●
1116 yk axis error: incorrect preceding sign
CAUSE
●
Program error; should not occur
REMEDY
●
1117 z axis error; GU1: incorrect preceding sign
CAUSE
●
Program error; should not occur
REMEDY
●
1118 z axis error; GU2: incorrect preceding sign
CAUSE
●
Program error; should not occur
REMEDY
●
1119 z axis error; GU3: incorrect preceding sign
CAUSE
●
Program error; should not occur
REMEDY
●

SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 125
1120 X-axis error: Reference error
CAUSE
●
Invalid reference point type in the machine data
REMEDY
●
Check machine data
1121 Y-axis error: Reference error
CAUSE
●
Invalid reference point type in the machine data
REMEDY
●
Check machine data
1122 xk-axis error: Reference error
CAUSE
●
Invalid reference point type in the machine data
REMEDY
●
Check machine data
1123 yk-axis error: Reference error
CAUSE
●
Invalid reference point type in the machine data
REMEDY
●
Check machine data
1124 Z-axis error, GU1: Reference error
CAUSE
●
Invalid reference point type in the machine data
REMEDY
●
Check machine data
1125 Z-axis error; GU2: Reference error
CAUSE
●
Invalid reference point type in the machine data
REMEDY
●
Check machine data
1126 Z-axis error, GU3: Reference error
CAUSE
●
Invalid reference point type in the machine data
REMEDY
●
Check machine data

19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 126
1127 X-axis error: incorrect acceleration
CAUSE
●
Invalid value in the machine data
REMEDY
●
Check the machine data
1128 Y-axis error: incorrect acceleration
CAUSE
●
Invalid value in the machine data
REMEDY
●
Check the machine data
1129 xk-axis error: incorrect acceleration
CAUSE
●
Invalid value in the machine data
REMEDY
●
Check the machine data
1130 yk-axis error: incorrect acceleration
CAUSE
●
Invalid value in the machine data
REMEDY
●
Check the machine data
1131 Z-axis error, GU1: incorrect acceleration
CAUSE
●
Invalid value in the machine data
REMEDY
●
Check the machine data
1132 Z-axis error; GU2: incorrect acceleration
CAUSE
●
Invalid value in the machine data
REMEDY
●
Check the machine data
1133 Z-axis error; GU3: incorrect acceleration
CAUSE
●
Invalid value in the machine data
REMEDY
●
Check the machine data