SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 79
729 VS: Upload data incorrect
CAUSE
Obsolete MVS software, MVS error.
REMEDY
Reboot; update eproms (MVS).
730 NF: software error
CAUSE
Incorrect message at NF (Info1)
REMEDY
If possible, ignore; possibly reboot.
731 NF: GLC NOK
CAUSE
Internal transmission error
REMEDY
Try again; if possible, ignore.
732 MA data: unknown spacer type
CAUSE
In aktuell.ma or *.vkl there is a spacer type which cannot be found in real.ma.
REMEDY
Establish consistency in the files aktuell.ma, *vkl and real.ma.
733 SF: unexpected input:
CAUSE
Incorrect message to single function (Info1), operator error during transition to single function or fatal
error handling ( start button not pressed )
REMEDY
If possible, ignore; possibly reboot.
734 SF: answer from wrong MC
CAUSE
System error
REMEDY
Reboot
735 SF: global communication not ok
CAUSE
Communication between machine controller and station computer disturbed.
REMEDY
Try communicating again.
19 Error Messages SIPLACE 80S/F/G User’s Manual
19.1 Error Messages Edition 12/96 from Software Version SR.009.xx
19 - 80
736 GK: Error in local machine data
CAUSE
There are no real or current machine data on the hard disk; the machine data cannot be converted
due to a structure error.
REMEDY
Write the MA data onto the hard disk properly.
737 GK: Error in machine data
CAUSE
The MA data (ideal) coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
738 GK: Error in set-up data
CAUSE
The set-up data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
739 GK: Error in cluster data
CAUSE
The cluster data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
740 GK: Error in fiducial data
CAUSE
The fiducial data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
741 GK: Error in package form data
CAUSE
The package form data coming from the line computer cannot be converted.
REMEDY
The correct data format must be sent.
742 LRS: Timeout during transmission to line computer
CAUSE
Released through IEC bus
REMEDY
Reboot
SIPLACE 80S/F/G User’s Manual 19 Error Messages
Edition 12/96 from Software Version SR.009.xx 19.1 Error Messages
19 - 81
743 LRS: Interface or driver not found
CAUSE
Does not occur
REMEDY
744 LRS: Command not in command list
CAUSE
LR SEND incorrect command received
REMEDY
If possible, ignore.
745 LRS: Conversion is not possible
CAUSE
Could not convert data for line computer telegrams SABR/SBES.
REMEDY
No
746 LRS: No communication with line computer
CAUSE
IEC bus is "blocked"
REMEDY
Reboot station and line computers.
747 DP: Data limits exceeded
CAUSE
Incorrect date input
REMEDY
Correct input date
748 DP: required equipment unknown
CAUSE
Possibly the TASKS.CFG file has been changed, or there is a software fault
REMEDY
Reboot with the supplied version of TASKS.CFG ; if necessary, notify AUT 5 BSM 14
Development department
749 No PCB barcode read
CAUSE
Barcode reader has been activated but barcode was not recognized
REMEDY
Make sure the barcode type is correct; make sure the mechanical distance is correct